Technical specification Rated input voltage: AC380~415V Range of input voltage: AC323~475V Frequency: 50Hz ± 10% Power factor: 0.92 Rated output voltage: DC110V or DC220V Range of output...
Add to Inquiry -
H61 22KV Amorphous Core Transformers
Traduction pour : Transfo H61 20KV 160kVA B2 H61 Transformer 15(20)kV 160kVA B2 Three-phase MV / LV distribution transformer with MV and LV windings in wound copper power P = 160KVA -...
Add to Inquiry -
Three-phase MV / LV distribution transformer with MV and LV windings in wound copper power P = 160KVA - Compliance: NFC 52 100 - 52 112 and 52 113 standard or equivalent in substance - Natural...
Add to Inquiry -
35KV FY Box Type Compact Substation
Features: 1) Smaller occupied area 2) Firm and reliable 3) Easy to move, beautiful and practical 4) Its cost is low, and the installation period is short
Add to Inquiry -
6KV VS1Indoor Vaccum Circuit Breaker
Environmental requirements The altitude shall not exceed 1000m; B. the environment temperature, maximum temperature + 40 ℃, the maximum temperature of 15 ℃ (only allow - 30 ℃ storage); C....
Add to Inquiry -
Environmental Conditions (1) Suitable Altitude: ≤2000mSuitable (2) Temperature: -40℃ ~ +55℃Relative (#) Humidity: Daily mean ≤95%, monthly mean ≤90% (4) Gradation of Earthquake Damage: ≤ Level 8
Add to Inquiry -
Service Conditions ◎ Ambient airtemperature: -15°C~+40°C; ◎ Relative humidity: Daily average 95%,and daily average of water vapor pressure < 2.2kPa; ◎ Monthly average «90%, and monthly...
Add to Inquiry -
Service environment a) Air temperature: Maximum temperature: +40°C; Minimum temperature:-15°C b) Humidity: Monthly average humidity 95%; Daily average humidity 90% . c)...
Add to Inquiry -
33KV Electrical Main Distribution Switchgear
Structure Description The switchgear is of box-type metal-enclosed fixed structure and the cubicle consists of profies and G profiles assembled by several connection pieces .It is divide into ...
Add to Inquiry -
KYN61 AC Metal Eclosed 15KV Switchgear Panel
Environmental Conditions 1) Suitable Temperature: -10℃ ~ +40℃, Daily average temperature:≤35℃. 2) Suitable Altitude: ≤1000m 3) Relative Humidity: Daily mean ≤95%, monthly mean ≤90% 4)...
Add to Inquiry -
13kv Incoming Outlet KYN28 Cabinet Switchgear
Structural characteristics 1. It has perfect mechanical and electrical double locking and anti error operation function. 2. The cabinet can be flexibly equipped with VS1, VYG, VD4, VN2 and...
Add to Inquiry -
6KV Staineless Steel Electric Switchgear
Service Conditions ◎ Ambient airtemperature: -15°C~+40°C; ◎ Relative humidity: Daily average 95%,and daily average of water vapor pressure < 2.2kPa; ◎ Monthly average «90%, and monthly...
Add to Inquiry