500kva Mini Substation Transformer 11000/6600/415v

Nov 03, 2022

500kva mini substation transformer 11000/6600/415v


three phase oil immersed transformer

H59 series oil immersed transformer implement the National Standard GB1094 Power Transformer and GB / T6451 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.

H59 series transformer is one kind of low loss copper winding product. It adopts high quality material, especially applying the new technology and new material to the insulation of the coil and transformer body, thus the no-load and the load loss are obviously reduced, the performance and structure are more reliable and superior.


Main Technical Parameters for H59 Series three-phase full-sealed non-excitaiton-tap-changing distribbution transformer

Rated
Power
(kva)

High
Voltage
(kv)

H.V.Tap
range

Low
Voltage
(kv)

Connection
symbol

Short
Circuit
Impendence
(%)

No-load loss(W)

On-load loss(W)

No load
current
(%)

H59

H60

H61

H59

H60

H61

30

22

±5%
±2x2.5%

0.4

Dyn11
Yyn0

4

130

110

100

600

600

600

2.1

50

170

150

130

870

870

870

2

63

200

180

150

1040

1040

1040

1.9

80

250

200

180

1250

1250

1250

1.8

100

290

230

200

1500

1500

1500

1.6

125

340

270

240

1800

1800

1800

1.5

160

400

310

280

2200

2200

2200

1.4

200

480

380

340

2600

2600

2600

1.2

250

560

460

400

3050

3050

3050

1.2

315

670

540

480

3650

3650

3650

1.1

400

800

650

570

4300

4300

4300

1

500

960

780

680

5150

5150

5150

1

630

4.5

1200

920

810

6200

6200

6200

0.9

800

1400

1120

980

7500

7500

7500

0.8

1000

1700

1320

1150

10300

10300

10300

0.7

1250

1950

1560

1360

12000

12000

12000

0.6

1600

2400

1880

1640

14500

14500

14500

0.6

2000

5

2830

2270

1940

17140

17140

17140

0.6

2500

3350

2690

2300

20260

20260

20260

0.5

Traduction pour : Transfo H61 20KV 160kVA B2


H61 Transformer 15(20)kV 160kVA B2


Three-phase MV / LV distribution transformer with MV and LV windings in wound copper power P = 160KVA

- Compliance: NFC 52 100 - 52 112 and 52 113 standard or equivalent in substance

- Natural cooling: ONAN

- MV voltage adjustment: by switch off +/- 5% in five (5) positions

- Type: on post H61

- Nominal power: 160KVA

- Primary rated voltage: 20,000V ± 5%

- Secondary voltage: 410V off-load between phases / 240V between phase and neutral

- Frequency: 50Hz

- Short-circuit voltage: 4%

- No-load loss less than or equal to 300W

- Load loss less than or equal to 2000W

- Coupling: Dyn11 with output neutral

- MV and LV crossings: in porcelain


Usually exported to Africa


MORE VIDEO


Facebook

https://www.facebook.com/bob.niu.35/


Youtube

www.youtube.com/channel/UC5IP4dL0UTQG4fgAOa3UhWA


Twitter

https://twitter.com/FengyuanE


Welcome to inquiry


Contact information:


Jiyuan Fengyuan Electrical Equipment Co., Ltd


Sales Department


Contact person:Mr Charles Du


E-mail:fengyuan800@outlook.com


Mobile:+8618639199897(Available for whatsapp,wechat,skype)


Add:Huling industrial zone,jiyuancity,henan province,China


TEL:+86-0391-2180800


FAX:+86-0391-2180818