High
video
High

High Voltage SF6 Gas Insulated Switchgear

High Voltage SF6 Gas Insulated Switchgear SF6 gas insulated switchgear is widely used in 10KV/20KV power distribution systems, and is a switch product for various types of urban and rural user power distribution systems. Switchgear is a modular unit mode, which can be combined according to...

Description

High Voltage SF6 Gas Insulated Switchgear

SF6 gas insulated switchgear is widely used in 10KV/20KV power distribution systems, and is a switch product for various types of urban and rural user power distribution systems. Switchgear is a modular unit mode, which can be combined according to different purposes. There are two types of fixed unit combinations and expandable units to meet the flexible use of compact switchgear in various substations.

SF6 gas insulated switchgear is a completely sealed system in which all live parts and switches are enclosed in a stainless steel housing. The entire switchgear is not affected by external environmental conditions, thus ensuring operational reliability and personal safety, and achieving maintenance-free. By choosing an expandable bus, any combination can be achieved to achieve full modularity. The safety insulation and shielding of the extended bus bar ensure high reliability and safety.


Air insulated ring network cabinet is a term corresponding to compact gas insulated ring network cabinet. In the early days, air insulated ring network cabinets used VEI vacuum or compressed air load switches, gas producing load switches, and other ring network cabinets. Later, with the widespread use of SM6, it became the main stream of air insulated ring network cabinets. Like other air ring network cabinets, the load switch has been replaced with an SF6 air bag type, which means that the load and grounding three-position switch is installed inside an epoxy resin cast insulation shell. SF6 as arc extinguishing and insulation medium

Air insulated ring network cabinet - expandable SF6 ring network cabinet, can be freely combined, has a small size, is safe and reliable, and does not require maintenance.


SF6 gas is used as insulation and arc extinguishing medium, and the constant magnetic field arc rotation method ensures strong arc extinguishing ability, good breaking performance, low overvoltage, long electrical life, and maintenance free arc extinguishing chamber.

The load switch - fuse combination electrical appliance has a three position function, perfect sealing, reliable operating mechanism and locking.

The grounding switch has a short-circuit closing function.

The cabinet body is formed by stamping and bending with aluminum coated zinc sheet, which is sturdy and reliable.

96 hour salt spray test conducted by the institution.

The insulated busbar of the main busbar shall be separated by metal partitions between cabinets and shall not generate eddy currents. Both ends of the busbar shall be sealed with insulation sealing.

Measures to prevent electric field concentration and partial discharge shall be taken at the junction of main bus.

The fuse grading cover ensures the insulation performance of the switch cabinet, without electric field concentration and partial discharge.

The ring network cabinet includes the following intervals: switch interval, bus interval, cable interval, mechanism interval, and control protection interval

1) Load switch

Load switches have a certain on-load breaking capacity, which means they can be energized to open and close under light loads, but they cannot be operated frequently. Generally, load switches are equipped with fuses and have stronger arc extinguishing ability than isolation switches.

2) Isolation switch

When the circuit breaker disconnects the circuit, the disconnection of the isolation switch allows for a clear separation of the live and dead parts, serving as an auxiliary switch.

Due to the lack of intuitive external indicators for the contact position of circuit breakers, and in some cases, it cannot be guaranteed that its indication is consistent with the position of the contact, it is necessary to use isolation switches to clearly separate the energized and non energized parts.

In addition, the isolation switch has a certain natural arc extinguishing ability, which is commonly used for the input and disconnection of low current equipment such as voltage transformers and lightning arresters, as well as the connection between a circuit breaker and several devices, making the switching of the circuit breaker through the isolation switch more flexible and convenient.

3) Circuit breaker

A switching device that can close, carry, and disconnect the current under normal circuit conditions, and can close, carry, and disconnect the current under abnormal circuit conditions within a specified time.

4) Grounding switch

Mainly used for equipment maintenance, in order to prevent sudden power calls during the maintenance process, both ends of the maintenance equipment must be grounded.

The grounding switch of the high-voltage distribution cabinet is generally grounded on the output load side. When repairing the load side of the high-voltage distribution cabinet (such as tightening bolts, disassembling cables, etc.), we need to disconnect the switch and close the grounding switch of the distribution cabinet at the same time. This can prevent sudden power calls from causing electric shock accidents, and also discharge the remaining charge, which is beneficial for maintenance safety

PRODUCT PHOTO

SF6 Insulated Ring Main Unit

High Voltage SF6 Gas Insulated Switchgear

SF6 Gas Insulated Switchgear

Environmental conditions

(1) Applicable altitude: ≤2000m applicable

(2) Temperature: -40℃ ~ +55℃ relative

(3) Humidity: daily average ≤95%, monthly average ≤90%

(4) Earthquake damage level: ≤8


Factory showing room

High Voltage Switchgear

10kv Switchgear For Sale

Certificates

Indoor Armored Metal Enclosed Switchgear

EXHIBITION

PACKING&DELIVERY

FAQ

Q5 : Is OEM/ODM available?

A: Yes, it is! Our products can be Customized. We have design and engineer teams,we can customize products according to customers' drawing or requirements.

Q6 : You are manufacturer or trading company?
A: We are factory, As a 100% professional manufacturer with 20 year's manufacturer experience, we could produce products according to customers' requirements and we could also control the quality of products 100%.

Q7 : Can the price be negotiated?

A: Yes, the price is negotiable. It can be changed according to your quantity or package

Q8 : How about inspection?

A: We have the whole inspection system from raw material to end products include temperature rise test,salt spraying test conductor type test,mechanical life test.

Q9 : What is payment terms?

A: T.T, Paypal,Western Union,Alibaba trade assurance and L/C is acceptable. 30% T/T in advance ,70% balance before shipment.

Q10 : What is the service offered by company?

A: We have the professional engineer team which can design and develop the mold to arrive different customer requirement.

We also have the sales team to offer good service from pre-sale to after-sale.



This product is usually customized.

We are a manufacturer and have a professional technical department that can design and provide solutions according to customer needs.

Please contact our sales personnel to obtain design drawings


Here are our customer examples for your reference

Zimbabwean clients

7.1Technical guarantee schedule : ring main units
ItemDescription UnitRequirement Guaranteed value
1.0 Type /model -StateRMU
2.0 Insulating medium-Vacuum /SF6SF6
2.1 Interrupting medium
Vacuum /SF6SF6
2.2 Transformer protection (Fuse/circuit breaker)
circuit breakercircuit breaker
3.0 Application standard-IEC and BSIEC
4.1 Nominal Voltage ratingkV1111
4.2 Maximum Voltage ratingkV1212
4.3 Rated Frequency Hz5050
4.4 Power Frequency withsand voltagekV2828
4.5 Impulse withstand voltage KVp9595
5.0 Rated current busbarsA630630
5.1 Rated Current cable (switch)A630630
5.2 Rated current (T-OFF)A125125
5.3 Rated current for circuit breakerA125125
6.0 Breaking Capacity


6.1 Closed loop (Cable switch)A630630
6.4 Short circuit breaking currentkA2020
6.5 Rated making capacity kA5050
6.6 Rated Short time current 3 seckA2020
7.0 Dimensions

CTCCCTC

Height mm
19501950

Widthmm
11701545

Depth mm
750750
8Are RMU's manufactured under license, if so state name of the company

HENAN FENGYUAN POWER TECHNOLOGY CO.,LTD.

IF NEED MORE DETAILES,PLEASE FEEL FREE YO CONTACT US


The best choice for the electrical industry! ! !

Please leave an inquiry for more detailed information about prices, packaging, shipping and discounts.

Hot Tags: high voltage sf6 gas insulated switchgear, China, manufacturers, suppliers, customized, Electrical Ring Main Units, Air Insulated Ring Main Unit, Electrical Ring Main Unit, Outdoor Gas Insulated Ring Main Unit, Metal Enclosed Ring Main Unit, rmu switchgear

(0/10)

clearall