Impact Resistance Corrosion Protection 12kv Electrical HV Switchgear
KYN28A-12 indoor metal armored withdrawable switchgear is mainly used for power plants, industrial and mining enterprises, as well as secondary substations in the power system for power collection, transmission, and starting of large motors. Implement control, protection, real-time monitoring, and measurement. It has a complete five prevention function and can be equipped with VS1 (ZN63A-12) vacuum circuit breakers, as well as VD4 vacuum circuit breakers produced by ABB. Currently, it is widely used in the 12KV market.
Description
Impact resistance Corrosion Protection 12kv electrical HV switchgear
Products Description
KYN series metal-clad removable enclosed switch cabinet (called switch cabinet for short). It is applicable for power receiving
and distribution in the 3.6-12Kv three-phase AC 50Hz single bus bar and single bus bar sectioning system. It has the functions of
controlling, protecting and monitoring the circuit.
Service Conditions
◎ Ambient airtemperature: -15°C~+40°C;
◎ Relative humidity: Daily average 95%,and daily average of water vapor pressure < 2.2kPa;
◎ Monthly average «90%, and monthly verage of water vapor pressure < 1.8kPa;
© Altitude: ^1000m;
◎ Seismic intensity: not beyond Ms8.
◎ Ambient air should be free of pollution of corrosive or flammable gas or vapor;
◎ No obvious vibration;
|
Main technical parameters |
|||
|
Rated voltage |
..................................... |
kV |
3.6、7.2、12 |
|
Rated frequency |
..................................... |
Hz |
50 |
|
Rated current of circuit breaker |
..................................... |
A |
630/4000 |
|
Rated current of switchgear |
..................................... |
A |
630/4000 |
|
Rated short-time withstand current (4S) |
..................................... |
kA |
20、25、31.5、40 |
|
Rated peak withstand current (peak) |
..................................... |
kA |
50、63、80、100 |
|
Rated short-circuit breaking current |
..................................... |
kA |
20、25、31.5、40 |
|
Rated insulation level 1min power frequency withstand voltage |
Pole-to-pole, pole-to- ground |
kV |
24、32、42 |
|
Between open contacts |
kV |
24、32、48 |
|
|
Lightning impulse withstand voltage (peak) |
Pole-to-pole, pole-to- ground |
kV |
40、60、75 |
|
Between open contacts |
kV |
46、70、85 |
|
|
The shell is IP4X, and it is IP2X when the compartment door and circuit breaker chamber door are opened |
|||
Features
1: STRICT protection step to ensure personal safety
2: The cable room can be installed as many as 9 single-core cables
3: Operation and testing positions will be established for the handcart, and both positions are equipped with safe and reliable positioning device and display device
4: The enclosure is completely assembled from aluminized and galvanized steel plate, which are machined and bent by machine tool and then bolted.
5: It has high mechanical strength and its neatness and beauty is ensured.
6: The switchboard door is sprayed with plastic, also has strong capacity of impact resistance and corrosion protection.
7: The primary switch may be provided with VD4 vacuum circuit breaker and C3 series of fixed type load switch from ABB, various domestic vacuum circuit breakers (such as VS1, VH1, VK, ZN28) may also be provided in lieu of the same foreign products.
8: Front door is installed with a observation window to check the operating state of the components inside the room
Five steps for power outage operation of KYN28 armored movable AC metal enclosed switchgear main power cabinet
1) Observe all cabinet related signals and confirm that all outgoing cabinet circuit breakers are in the open position.
2) The switching switch causes the circuit breaker to open and power off, while the red closing indicator light on the instrument door is off and the green opening indicator light is on. Upon checking other relevant signals, everything is normal and the power outage is successful. (When operating the on/off switch, rotate the operating handle counterclockwise to the indicated open position on the panel. After releasing the handle, the operating handle should automatically reset to the pre open position.)
3) Insert the circuit breaker handcart handle into the handle socket and press it down with force. Rotate the handle counterclockwise for about 20 turns, and remove the handle when it is clearly blocked and accompanied by a "click" sound. At this time, the handcart is in the test position, and the aviation plug is unlocked. Open the handcart compartment door and manually release the aviation plug. (Handheld vehicle circuit disconnected)
4) Observe the live display and confirm that it is not live before continuing operation. (The lower door of the incoming cabinet has a Electromagnetic lock for forced locking, which can only be unlocked when the incoming terminal is not electrified, but can also be unlocked with a key for emergency unlocking when the incoming terminal is electrified. Opening the incoming circuit breaker does not mean that the incoming cabinet is not electrified. If the external power supply is not stopped, the cable chamber is electrified at this time, and forced entry is life-threatening.)
5) Open the lower door, conduct electrical testing (necessary), discharge (necessary), and hang the grounding wire (necessary). Maintenance personnel can enter for maintenance and repair.
4、 The operation procedure of the backup power cabinet is the same as that of the main power cabinet.
As the relevant content has already been introduced earlier, which includes the seven steps of power transmission operation and the five steps of power outage operation, we will not elaborate further.
5、 Three steps for operating the measuring cabinet
1) The measuring handcart is directly connected to the moving and stationary contacts, and does not have the ability to break or extinguish arcs. It must not be shaken in or out with load.
2) The metering handcart and the circuit breaker of the incoming switchgear have electrical and mechanical interlocks. Only after the main power supply (backup power supply) circuit breaker is opened can the metering handcart be operated to swing in or out. Forced operation is not allowed to avoid damaging the interlocking device. When the measuring handcart is forcibly shaken out with load, the main power (backup power) circuit breaker will automatically open to avoid personal injury or death.
3) The method of shaking in and out the measuring handcart is the same as that of the circuit breaker handcart.
Products Photo








Factory workshop


Certificate




Packing&delivery


Exhibition

FAQ
Q5 : Is OEM/ODM available?
A: Yes, it is! Our products can be Customized. We have design and engineer teams,we can customize products according to customers' drawing or requirements.
Q6 : You are manufacturer or trading company?
A: We are factory, As a 100% professional manufacturer with 20 year's manufacturer experience, we could produce products according to customers' requirements and we could also control the quality of products 100%.
Q7 : Can the price be negotiated?
A: Yes, the price is negotiable. It can be changed according to your quantity or package
Q8 : How about inspection?
A: We have the whole inspection system from raw material to end products include temperature rise test,salt spraying test conductor type test,mechanical life test.
Q9 : What is payment terms?
A: T.T, Paypal,Western Union,Alibaba trade assurance and L/C is acceptable. 30% T/T in advance ,70% balance before shipment.
Q10 : What is the service offered by company?
A: We have the professional engineer team which can design and develop the mold to arrive different customer requirement.
We also have the sales team to offer good service from pre-sale to after-sale.
This product is usually customized.
We are a manufacturer and have a professional technical department that can design and provide solutions according to customer needs.
Please click on the button below to send us the information, and our sales personnel will contact you to provide you with the design drawings
Here are our customer examples for your reference
IF NEED MORE DETAILES,PLEASE FEEL FREE YO CONTACT US
Hot Tags: impact resistance corrosion protection 12kv electrical hv switchgear, China, manufacturers, suppliers, customized