40.5kv Removable Indoor AC Metal-enclosed KYN Switchgear
1. Switch cabinet (also known as complete switch or complete distribution device): It is an electrical equipment mainly composed of circuit breakers; It refers to that the manufacturer assembles relevant high and low voltage electrical appliances (including control appliances, protection appliances, measuring appliances), buses, current carrying conductors, insulators, etc. in closed or open metal cabinets according to the requirements of the electrical primary main wiring diagram, as devices for receiving and distributing electric energy in the power system. 2. High voltage switchgear: A general term for high-voltage switches mainly used for power generation, transmission, distribution, and energy conversion, as well as control, measurement, protection devices, electrical connections (busbars), enclosures, support components, etc.
Description
40.5kv Removable Indoor AC Metal-enclosed KYN Switchgear
Products Description
|
Model |
KYN61-40.5 |
|
Rated voltage |
40.5 |
|
Frequency |
50HZ |
|
Rated Current |
1250A/1600A/2000A |
|
IP Grade |
IP3X |
|
Environment Temperature |
-10 C~+40 C |
|
Accessories |
specification |
|
Maintenance Instruction |
Must be cleaned and put in a dry place |
KYN61-40.5 removable AC metal-clad switchgear applies to 40.5kV, 3 phase, AC and 50/60Hz electrical power network for receiving and distributing power energy and also for control, monitor and protect ion. It is applicable in general power system and occasions with frequent operation. The product conforms to GB3906: 3~35kV AC Metal Enclosed Switchgear, IEC60694 & GB/T11022: The common technical clauses of HV Switchgear and controlgear Standard, DL/T404-1997: Order Technical term of Indoor AC HV Switchgear and IEC62271-200 1~52kV AC Metal Enclosed Switchgear and controlgear standard.
Environmental Conditions
1) Suitable Temperature: -10℃ ~ +40℃, Daily average temperature:≤35℃.
2) Suitable Altitude: ≤1000m
3) Relative Humidity: Daily mean ≤95%, monthly mean ≤90%
4) Gradation of Earthquake Damage: ≤ Level 8
Applicable occasions should be free from corrosives, inflammables and vapor.
Summary:
KYN61-40.5 switchgear is three phase AC 50 Hz,rated voltage of 40.5 KV indoor power distribution equipment.As power plants ,substations and industrial distruction of electric energy only ,and has a circuit implementation of control,protection and monitoring function .
Structure Description:
Switchgear according G83906 and IEC298 standards and design,And can be removed from the cabinet as a whole unit (trolley )components .
Cabinet structure are made of aluminum deposited zine plate or galvanized sheet assembled with both connection ,separate circuit breaker switchgear roon ,bus room ,cable room and instrument room,All metal components are grounded ,each compartment of the main circuit .system have separate pressure release channel in the cable compartment can be set 10*60mm ground bus .
Main characteristics:
1.The use of assembled cabinet structure ,circuit breaker handcart floorstanding structure ,
Samall size:
2.Optional: The company vacuum breaker VW1-40.5,xiamen huadian vacumm breaker VEP-40.5 ,similar circuit breaker are interchangeable .
3.Equipped with special transport vehicles can lift ,transport vehicles amd cabinet accurate positioning ,locking and reliable
4.The main switch ,handcart ,door interlock switch between mandatory mechanical locking methods are used to meet the ‘Five Anti’ interlock function .
5.all operation can be carried out at the door closed state ,to protect the safety of the operator .
6.Cable ample room space ,can be connected to multiple cables ,and overhead outlet .
7.Shell protection grade IP3X,handcart room door open between the various compartments protection class IP2X.
8.The material can be galvanized sheet can be deposited alumimum zinc plate production .
2.Main Electric Parameters
|
No. |
Items |
Unit |
Parameters |
||
|
1 |
Rated voltage |
KV |
40.5 |
||
|
2 |
Rated frequency |
Hz |
50 |
||
|
3 |
The main busbar rated current |
A |
1250,1600,1200 |
||
|
4 |
Branch busbar rated current |
A |
630/1250/ 1600 |
||
|
5 |
Rated insulation level |
Power frequency withstand voltage in 1min (Effective value) |
Phase-phase, Phase-ground |
KV |
95 |
|
|
KV |
115 |
|||
|
Lightning Impulse Withstand Voltage (peak value) |
Phase-phase, Phase-ground |
KV |
185 |
||
|
|
KV |
215 |
|||
|
Power frequency withstand voltage of auxiliary control circuit |
|
V |
2000 |
||
|
6 |
Rated short circuit breaking current |
KA |
25/31.5 |
||
|
7 |
Rated short circuit closing current (peak value) |
KA |
63/80 |
||
|
8 |
Rated short-time withstand current (4S) |
KA |
25/31.5 |
||
|
9 |
Rated peak withstand current |
KA |
63/80 |
||
|
10 |
Rated voltage of auxiliary control circuit |
V |
-110,-220,~220 |
||
|
11 |
Protection grade |
|
Enclosure IP4X, IP2X When the door of the circuit breaker opens |
||
|
12 |
Outline size (width * depth * height) |
mm |
1400(1200)*2800(2600)*2600(*includes an internal digital SF6 handcart scheme) |
||
|
13 |
weight |
kg |
~2300 |
||
1、 Daily maintenance and repair
(1) Appearance inspection of the switchgear.
The shell of the switchgear shall be free from deformation and damage; The protective paint is free from severe rust, damage, and peeling; The cabinet body is firmly installed, and the appearance is clean and free of debris; The nameplate and identification of the switchgear shall be neatly pasted without detachment.
(2) Check the operating status parameters of the switchgear.
The instrument and meter indications are normal (compared to daily operating values, there is no difference or no significant difference and corresponds to the equipment status).
(3) The relevant components, electrical contacts, wires, and cables of the switchgear shall not exceed the specified temperature.
Use an infrared thermometer to measure the operating temperature of visible related devices, electrical contacts, wires, and cables to be ≤ 60 ℃, and there is no odor inside the cabinet.
(4) Whether the switch position, indicator light indication and instrument display are correct, and whether the position of each transfer switch is normal.
The opening and closing positions of the switch are correct, there is no alarm indication, and the transfer switch is in the specified position.
Products Photo







Factory workshop


Certificate




Packing&Delivery


Exhibition


FAQ
Q5 : Is OEM/ODM available?
A: Yes, it is! Our products can be Customized. We have design and engineer teams,we can customize products according to customers' drawing or requirements.
Q6 : You are manufacturer or trading company?
A: We are factory, As a 100% professional manufacturer with 20 year's manufacturer experience, we could produce products according to customers' requirements and we could also control the quality of products 100%.
Q7 : Can the price be negotiated?
A: Yes, the price is negotiable. It can be changed according to your quantity or package
Q8 : How about inspection?
A: We have the whole inspection system from raw material to end products include temperature rise test,salt spraying test conductor type test,mechanical life test.
Q9 : What is payment terms?
A: T.T, Paypal,Western Union,Alibaba trade assurance and L/C is acceptable. 30% T/T in advance ,70% balance before shipment.
Q10 : What is the service offered by company?
A: We have the professional engineer team which can design and develop the mold to arrive different customer requirement.
We also have the sales team to offer good service from pre-sale to after-sale.
This product is usually customized.
We are a manufacturer and have a professional technical department that can design and provide solutions according to customer needs.
Please click on the button below to send us the information, and our sales personnel will contact you to provide you with the design drawings
Here are our customer examples for your reference
IF NEED MORE DETAILES,PLEASE FEEL FREE YO CONTACT US
Hot Tags: 40.5kv removable indoor ac metal-enclosed kyn switchgear, China, manufacturers, suppliers, customized, withdrawable switchgear, high voltage switchgear and controlgear, metal-clad switchgear, metal enclosed interrupter switchgear, 10kv Switchgear Cabinet Metal Enclosure, indoor switchgears