Gas Insulated Metal Enclosed Switchgear
Gas Insulated Metal Enclosed Switchgear This product is used in three-phase AC 10KV, 50Hz power system. It is used in industrial and mining enterprises, high-rise buildings, residential quarters, prefabricated substations and other places to open and close load currents, fault currents, control...
Description
Gas Insulated Metal Enclosed Switchgear
Our inflatable SF6 metal seal full insulation series ring network switch cabinet has passed the type test of the national occlusal electrical testing center. Widely used in 10KV/6K power distribution system, it is the preferred switch product for various users in urban and rural areas.
switch cabinet is modular unit mode, which can be combined according to different purposes. By the combination of fixed units and expandable units, which substation meets the need of compact switchgear flexible use.
Inflatable ring SF6 cabinet is divided into non-expandable standard configuration and expandable standard configuration. Due to the combination of full module and half module and its own scalability, it has extremely special flexibility. SF6 inflatable ring cabinet implemented GB standard. Under the condition of the interior (20 ℃) run the design life of more than 30 years.
This product is used in three-phase AC 10KV, 50Hz power system. It is used in industrial and mining enterprises, high-rise buildings, residential quarters, prefabricated substations and other places to open and close load currents, fault currents, control and protect lines and distribution transformers.
Air insulated ring network cabinet is a term corresponding to compact gas insulated ring network cabinet. In the early days, air insulated ring network cabinets used VEI vacuum or compressed air load switches, gas producing load switches, and other ring network cabinets. Later, with the widespread use of SM6, it became the main stream of air insulated ring network cabinets. Like other air ring network cabinets, the load switch has been replaced with an SF6 air bag type, which means that the load and grounding three-position switch is installed inside an epoxy resin cast insulation shell. SF6 as arc extinguishing and insulation medium
Air insulated ring network cabinet - expandable SF6 ring network cabinet, can be freely combined, has a small size, is safe and reliable, and does not require maintenance.
SF6 gas is used as insulation and arc extinguishing medium, and the constant magnetic field arc rotation method ensures strong arc extinguishing ability, good breaking performance, low overvoltage, long electrical life, and maintenance free arc extinguishing chamber.
The load switch - fuse combination electrical appliance has a three position function, perfect sealing, reliable operating mechanism and locking.
The grounding switch has a short-circuit closing function.
The cabinet body is formed by stamping and bending with aluminum coated zinc sheet, which is sturdy and reliable.
96 hour salt spray test conducted by the institution.
The insulated busbar of the main busbar shall be separated by metal partitions between cabinets and shall not generate eddy currents. Both ends of the busbar shall be sealed with insulation sealing.
Measures to prevent electric field concentration and partial discharge shall be taken at the junction of main bus.
The fuse grading cover ensures the insulation performance of the switch cabinet, without electric field concentration and partial discharge.
The ring network cabinet includes the following intervals: switch interval, bus interval, cable interval, mechanism interval, and control protection interval
1) Load switch
Load switches have a certain on-load breaking capacity, which means they can be energized to open and close under light loads, but they cannot be operated frequently. Generally, load switches are equipped with fuses and have stronger arc extinguishing ability than isolation switches.
2) Isolation switch
When the circuit breaker disconnects the circuit, the disconnection of the isolation switch allows for a clear separation of the live and dead parts, serving as an auxiliary switch.
Due to the lack of intuitive external indicators for the contact position of circuit breakers, and in some cases, it cannot be guaranteed that its indication is consistent with the position of the contact, it is necessary to use isolation switches to clearly separate the energized and non energized parts.
In addition, the isolation switch has a certain natural arc extinguishing ability, which is commonly used for the input and disconnection of low current equipment such as voltage transformers and lightning arresters, as well as the connection between a circuit breaker and several devices, making the switching of the circuit breaker through the isolation switch more flexible and convenient.
3) Circuit breaker
A switching device that can close, carry, and disconnect the current under normal circuit conditions, and can close, carry, and disconnect the current under abnormal circuit conditions within a specified time.
4) Grounding switch
Mainly used for equipment maintenance, in order to prevent sudden power calls during the maintenance process, both ends of the maintenance equipment must be grounded.
The grounding switch of the high-voltage distribution cabinet is generally grounded on the output load side. When repairing the load side of the high-voltage distribution cabinet (such as tightening bolts, disassembling cables, etc.), we need to disconnect the switch and close the grounding switch of the distribution cabinet at the same time. This can prevent sudden power calls from causing electric shock accidents, and also discharge the remaining charge, which is beneficial for maintenance safety
Environmental Conditions
(1) Suitable Altitude: ≤2000mSuitable
(2) Temperature: -40℃ ~ +55℃Relative
(#) Humidity: Daily mean ≤95%, monthly mean ≤90%
(4) Gradation of Earthquake Damage: ≤ Level 8
Technical characteristics
1. The vacuum circuit breaker is a built-in type and adopts a vacuum interrupter, which is maintenance-free and has a long service life. The number of operations can reach 10,000 times.
2. The load switch or fuse can also be built in according to user requirements.
3. Adopt advanced scientific design, simple structure and complete protection function.
4. With interlocking device, there are 5 kinds of isolating switches to prevent load opening and closing.
5. The upper and lower isolating switches are equipped with double-break rotary isolating switches
6. The upper and lower isolating switches use double-break rotary isolating switches. Shell protection grade: IP40, when opening the door: IP20.
PRODUCT PHOTO








FACTORY

Certificates

COMPANY OVERVIEW

EXHIBITION

Packing & Delivery
1. The packaging of gas insulated metal enclosed switchgear meets the requirements of product packaging specifications, and the packaging of export products meets the requirements of export product packaging technical conditions.
2. On-site installation of gas insulated metal enclosed switchgear shall be carried by hoisting or forklift. Tilt, inversion and vigorous movement are not allowed during handling.
3. Gas insulated metal enclosed switchgear (even with outer packaging) should not be stored outdoors for a long time, generally not more than one year. Switch cabinets that are not used for a long time should be stored in a dry and ventilated indoor warehouse.

Notices for order placement
The undermentioned data shall be provided by user during order placement:
1. Main circuit wiring diagram, indicating the technical parameters of each component
2. Schematic diagram of auxiliary circuit
3. Equipment table
4. Floor plan
5. Other drawings and documents for special needs
This product is usually customized.
We are a manufacturer and have a professional technical department that can design and provide solutions according to customer needs.
Please contact our sales personnel to obtain design drawings
Here are our customer examples for your reference
Zimbabwean clients
| 7.1 | Technical guarantee schedule : ring main units | ||||
| Item | Description | Unit | Requirement | Guaranteed value | |
| 1.0 | Type /model | - | State | RMU | |
| 2.0 | Insulating medium | - | Vacuum /SF6 | SF6 | |
| 2.1 | Interrupting medium | Vacuum /SF6 | SF6 | ||
| 2.2 | Transformer protection (Fuse/circuit breaker) | circuit breaker | circuit breaker | ||
| 3.0 | Application standard | - | IEC and BS | IEC | |
| 4.1 | Nominal Voltage rating | kV | 11 | 11 | |
| 4.2 | Maximum Voltage rating | kV | 12 | 12 | |
| 4.3 | Rated Frequency | Hz | 50 | 50 | |
| 4.4 | Power Frequency withsand voltage | kV | 28 | 28 | |
| 4.5 | Impulse withstand voltage | KVp | 95 | 95 | |
| 5.0 | Rated current busbars | A | 630 | 630 | |
| 5.1 | Rated Current cable (switch) | A | 630 | 630 | |
| 5.2 | Rated current (T-OFF) | A | 125 | 125 | |
| 5.3 | Rated current for circuit breaker | A | 125 | 125 | |
| 6.0 | Breaking Capacity | ||||
| 6.1 | Closed loop (Cable switch) | A | 630 | 630 | |
| 6.4 | Short circuit breaking current | kA | 20 | 20 | |
| 6.5 | Rated making capacity | kA | 50 | 50 | |
| 6.6 | Rated Short time current 3 sec | kA | 20 | 20 | |
| 7.0 | Dimensions | CTC | CCTC | ||
| Height | mm | 1950 | 1950 | ||
| Width | mm | 1170 | 1545 | ||
| Depth | mm | 750 | 750 | ||
| 8 | Are RMU's manufactured under license, if so state name of the company | HENAN FENGYUAN POWER TECHNOLOGY CO.,LTD. | |||
Contact us:
Henan Fengyuan Power Technology Co.,ltd
Contact person:Mr Charles Du
E-mail: Fengyuan800@outlook.com
Mobile:008618639199897 (Available for Whatsapp,Wechat,Skype)
Hot Tags: gas insulated metal enclosed switchgear, China, manufacturers, suppliers, customized