FENGYUAN Power Technology Come Back From Vietnam Electricity Exhibition 25th July

Jul 25, 2023

Photos of Vietnam Power Exhibition

 

20230722101347

20230722101355

20230722101409

20230722101419

20230722101429

20230722101453

20230722101502

20230722101510

 

 

our factory product photo

 

high and low voltage switchgear

GCS/MNS/GCK/GGD TYPE

KYN28 HV switchgear

SF6 GIS switchgear

 

H59/H61 oil immersed transformer

 

prefabricated box substation

 

20230320093328

20230602101509

20230602101515

JP5

KYN28A

KYN28A-12 123

MNS1

20230427154939

20230427155105

 

 

 

This product is usually customized.
We are a manufacturer and have a professional technical department that can design and provide solutions according to customer needs.
Please click on the button below to send us the information, and our sales personnel will contact you to provide you with the design drawings

 

Here are our customer examples for your reference

Vietnamese customers

Data Sheet N° 1-A: Transformer H61 20kV/400V of 100kVA

DESIGNATIONS

UNITS

SPECIFIC DATA

CANDIDATE DATA

Maker

 

To be indicated

 

Reference standard

 

IEC 60076

 

Type

 

Phase

 

Vat

 

Hermetic

 

Execution

 

Tropicalized

 

Dielectric

 

PCB-free oil

 

Installation

 

On pole

 

Operating ambient temperature

°C

45

 

Rated frequency

Hz

50

 

Rated power

Kva

100

 

Rated primary voltage

Kv

20

 

Isolation level assigned to primary school

Kv

24

 

Number of phases in primary school

 

03

 

Secondary voltage

V

400/230

 

Voltage adjustment range on the M side when unladen

%

±2.5

 

Coupling

 

DYn11

 

Short circuit voltage

%

4 – 4.5

 

Neutral sized for one load

%

100

 

Maximum vacuum losses

W

230 - 460

 

Losses due to Maxi load

W

1450 - 2350

 

Maximum steady-state oil temperature

°C

55

 

Maximum temperature of the windings in steady state

°C

60

 

Winding material

 

Electrolytic copper

 

Maximum noise level

Db

52

 

50Hz industrial frequency hold, 1 min

Kv

50 – 70

 

Shock wave resistance (1.2/50 micros)

Kv

125 - 170

 

Cooling

 

ONAN

 

Nameplate

 

01

 

Grounding connection

 

01

 

Dimensions Height/width/depth

mm x mm x mm

1200 X 1270 X 820

 

Total mass of transformer including oil

Kg

700

 

Oil mass

Kg

160

 

PAINT

 

 

 

Tropicalized and anti-rust

 

 

Number

Layers

 

 

 

Binder

 

 

 

Colour

 

 

 

Plans and technical diagrams to be provided.

 

 

IF NEED MORE DETAILES,PLEASE FEEL FREE YO CONTACT US