Problems and precautions in the operation and maintenance process of the box transformer substation

Jun 02, 2023

Problems and precautions in the operation and maintenance process of the box transformer substation

 

The Problem

 

1. Parts aging

The lightning arrester installed inside the metal box transformer housing malfunctions, affecting the entire internal equipment. If not properly maintained in a short period of time, it is easy to cause internal facilities to age; At the same time, overvoltage caused by lightning strikes can easily cause damage to interaction and communication facilities, affecting the normal operation of the circuit.

2. Severe operating environment

Usually, the operating environment should not have strong electromagnetic waves, and the altitude of the installation location should not exceed 2000 meters. The ambient temperature should be controlled between -30 to 40 degrees Celsius, and the wind pressure should not exceed 600pa. Therefore, if located in a harsh environment, faults are prone to occur.

3. Improper maintenance and upkeep

Although the material performance of the metal box transformer housing is relatively good, long-term exposure to wind and sun can easily cause corrosion and weathering of the equipment. The door body is not tightly closed, and even leaks rain and water, resulting in internal equipment heating. When the internal temperature is high and the external environment decreases, small animals will instinctively enter the inside of the box, causing short circuits in the transformer equipment and even damage to distribution components.

 

Management considerations

 

1. Strengthen lightning protection of distribution lines

The failure of the lightning arrester can directly lead to the failure of the metal box transformer casing. Therefore, it is ensured that the protection range of the lightning arrester can cover the entire box area, and the insulation treatment is thickened at a fixed position to improve the ability of the distribution line to respond to lightning strikes. At the same time, a metal zinc oxide lightning arrester is installed at the connection position between the outgoing cable and the isolation switch to prevent lightning from entering the transformer through the cable and avoid the generation of overvoltage, It should be noted that all incoming and outgoing cables of the transformer are shielded cables and suppressors are installed at the control and communication interface positions.

2. Strengthen the maintenance of distribution lines

Regularly inspect the distribution lines, strengthen the inspection work of the distribution lines in the area, and promptly detect any abnormal phenomena. In unattended situations, smoke temperature alarm signals should be installed, directly connected to the monitoring center, and faults should be detected and repaired in a timely manner.

3. Strengthen the heat dissipation work of the substation

The premise for the safe operation of the metal box transformer casing is heat dissipation. Firstly, the casing must have good heat dissipation performance and adopt the body heat dissipation design. The structure follows the principle of Xia Xi's cold air upper exhaust hot air. The base adopts a hollow design, and the lower space of the foundation is lower than the positive and negative zero bottom surface. Firstly, it can avoid the temperature of the ground, and secondly, it can create convection between the cold air inside the foundation and the internal hot air. The hot air is discharged from the heat dissipation hole and absorbed from the bottom.

At present, the metal box transformer casing is of great scale in the power system, and its safe and stable operation is crucial. Based on the problems encountered in practical applications, the above points for operation and maintenance management are proposed to ensure the operation status of the metal box transformer casing to a large extent

 

PRODUCT LINK

http://www.switchgear-china.com/box-type-compact-substation/prefabricated-substation/24kv-prefabricated-substation.html

 

PRODUCT PHOTO

20230427155129

20230427155211

20230427155230

20230427155239

box type substation 3

Box type substation 16

prefabricatedboxtypesubstation

 

This product is usually customized.
We are a manufacturer and have a professional technical department that can design and provide solutions according to customer needs.
Please contact our sales personnel to obtain design drawings

Here are our customer examples for your reference

TECHNICAL REQUIREMENTS AND CHARACTERISTICS OF EQUIPMENT
Re:82 sets compact substation
Item-
No.
Schedule of Technical Data Unit Required (at
3000 m
Offered Data
System Data Requirements
1.05.10 Stranded copper conductor for earthing
Manufacturer -
Material - copper
Cross-section mm2 >50
Length m >40
1.05.11 Earthing rods
Manufacturer -
Type -
Materia! -
Length m
Sections per rod pcs
1.6 Compact Substations (Option 1)
Manufacturer - fengyuan
Type - OutDoor
Overall protection class for complete substation - IP 44 IP 44
Material of enclosure - GI
Overall dimensions (W x L x H)
for S/S with 1x50 kVA transformer mm/mm/mm 3000x1850x2150
■ for S/S with 1x100 kVA transformer mm/mm/mm 3000x1850x2150
for S/S with 1x160 kVA transformer mm/mm/mm 3000x1850x2150
• for S/S with 1x250 kVA transformer mm/mm/mm 3000x1850x2150
Overall weight
■ for S/S with 1x50 kVA transformer kg 1000kg.
■ for S/S with 1x100 kVA transformer kg 1000kg.
■ for S/S with 1x160 kVA transformer kg 1000kg.
■ for S/S with 1x250 kVA transformer kg 1000kg.
1.6.1 20 kV Switchgear equipment
Manufacturer - Chnt / Equivalent
Type - Indoor RMU

 

IF NEED MORE DETAILES,PLEASE FEEL FREE YO CONTACT US