Kyn550-12 Indoor High Voltage Switchgear
Kyn550-12 indoor armored shifting AC metal closed switch equipment (hereinafter referred to as KYN550-12 switch cabinet) is ST's smallest complete set of power distribution equipment applied to 12kV three-phase AC 50Hz single bus and single bus segment system. KYN550-12 is to prevent loading...
Description
Kyn550-12 indoor armored shifting AC metal closed switch equipment (hereinafter referred to as KYN550-12 switch cabinet) is ST's smallest complete set of power distribution equipment applied to 12kV three-phase AC 50Hz single bus and single bus segment system. KYN550-12 is to prevent loading of push-pull circuit breaker handcart, prevent false or circuit breaker, to prevent the earthing switch is in the closed position close circuit breaker, avoid straying into charged across the room, to prevent the mistake when charged us grounding switch "five prevention" interlock function, shenton technology of indoor solid sealing medium pressure vacuum circuit breaker handcart, power distribution equipment is a kind of superior performance. The size design of KYN550-12 saves a lot of power distribution space for commercial and industrial buildings, real estate, data centers and other industrial power grids where there is a need for miniaturization.

Standard
This switch cabinet meets iec62271-200, GB3906, DL/T404 and other standard requirements. The kyN550-12 switch cabinet housing is rated IP4X and IP2X when the breaker room door is opened and the handcart is removed.
Service environment conditions
Normal service conditions
Ambient air temperature: upper limit +40℃, lower limit -25℃;
Altitude: the maximum altitude of the installation site is 1000m.
Ambient temperature: the daily average relative humidity is less than 95% and the monthly average relative humidity is less than 90%.
Earthquake intensity does not exceed 8 degrees;
The surrounding air should be free from corrosive or flammable gases, water vapor and other obvious pollution;
No serious pollution and frequent violent vibration. Severity design for severe conditions shall meet class 1 requirements.
Cabinet put oneself in another's position is introduced
The switchgear is designed according to GB3906 and IEC62271-200 standard of armored metal enclosed switchgear. The whole cabinet is composed of two parts (i.e. the handcart) and the cabinet is divided into four separate compartments, with overhead inlet and outlet lines, cable outlet lines and other functional programs, after the arrangement and combination can become the power distribution device to meet the needs of users. This switch equipment in addition to meet the domestic after maintenance of the user habits, but also provides the options of maintenance before the cabinet. Cabinet maintenance design can be installed from the front debugging and maintenance, so used as a single bus section system, back to back or face to face installation, in addition to double arrangement can also be installed on the wall, further reduce the floor area. The utility, adaptability and flexibility of switch equipment are improved, and the investment cost is reduced under the premise of meeting the safety performance.
Working principle of circuit breaker handcart
When the handcar is transported into the circuit breaker room of the cabinet with the transfer vehicle, it can be reliably locked in the test position; Cabinet position display lamp shows its position. And only after the safety lock, can shake the propulsion mechanism, the handcart to the working position. After the handcar arrives at the working position, the push handle will not move, and the corresponding position indicator will show its position. The mechanical interlock of handcart can reliably ensure that the circuit breaker can be closed only in the working position or test position of handcart; And the circuit breaker can be moved only when the handcar is on. Close the door operation can be realized.
Compartment
The main electrical components of the switch cabinet have their own separate compartments, namely: instrument room A, circuit breaker room B, bus room C, cable room D, the protection level of each compartment reaches IP2X; In addition to the instrument room, the other three high-pressure chambers have their own pressure relief channels.
Instrument room A
Relay instrument room can be installed relay protection elements, meters, live monitoring indicators, and special requirements of secondary equipment. The control circuit is laid in a slot with sufficient space and has a metal cover plate to isolate the secondary circuit from the high pressure chamber.The left line groove is reserved for control of the introduction and extraction of small line, switch cabinet itself internal small line laying on the right side. When necessary, there can be a small bus through hole on the roof of the relay instrument room for convenient construction. When wiring, the top cover plate of the instrument room can be turned over to facilitate the installation of the small bus.
Breaker room B
Rails are installed on both sides of the compartment for the handcart to slide from the isolation/test position to the working position in the cabinet. When the handcart moves from the disconnect position/test position to the working position, the valve door on the upper and lower static contact box is linked with the handcart and automatically opens at the same time; When moving in the opposite direction, the valve is automatically closed until the handcar returns to a certain position and completely covers the static contact box, forming effective isolation. At the same time, the linkage of the upper and lower valves can lock the valve on the charged side during maintenance, so as to ensure that the maintenance personnel do not touch the charged body. The handcart can also be operated when the breaker room door is closed. Through the door observation window, you can observe the position, closing, brake display and energy storage status of the handcar in the other room.
Busbar chamber C
The main bus is a single splicing through connection, fixed through the support bus and static contact box. The main bus and connecting bus are D - shaped or rectangular. Used for large current load with double bus. The branch bus is bolted to the static contact box and the main bus, and no other support is required. The main bus and the branch bus are covered with heat shrinkable sleeve, the lap joint is made of flame retardant T-type insulation cover to ensure reliable composite insulation, and the adjacent cabinet bus is fixed with wall bushing.
Cable room D
The current transformer is installed on the back wall of the cable room and the grounding switch is installed on the fixing plate of the contact box to avoid the distortion of the operating shaft of the grounding switch. Cable indoor space is large, can be connected to multiple cables, cable connection height is high, convenient installation.

About us:


Henan Fengyuan Power Technology Co., Ltd., founded in 2010 with registered capital of 20 million yuan, a fixed asset of 50 million yuan, more than 200 employees and an annual output value of nearly 100 million yuan, located in Jiyuan City, Henan, China.
Fengyuan focuses on producing KYN61-40.5 power distributing cabinet, KYN28-12, XGN15-12, HXGN15-12 and other model medium and high voltage electric full set switchgear equipment, movable transformer prefabricated substation, generator automatic controlling cabinet, dual power automatic switching device, draw-out low voltage switchgear GCK, GCS, MNS series, fixed low voltage switchgear GGD series, and other controlling, metering, switching box or cabinet series products.
FAQ:
1) Q:Is your price Competitive?
We have our own Factory. Thanks to strong production and distribution system, we promise to offer our customers the most competitive price.
2) Q: How about the delivery time?
A:Usually we need about 6-20 days produce time. 15-20 days after receiving the full payment.
3) Q: What about the guarantee?
All products before delivery to provide a certificate of product quality,24hours after sale service for you service.
4) Q: What's the payment method?
A:30%T/T as Deposit, Balance 70%TT before products leave our factory.
Hot Tags: kyn550-12 indoor high voltage switchgear, China, manufacturers, suppliers, customized