Metal
video
Metal

Metal Clad Low Voltage Switchgear

GCK type low voltage switchgear is suitable for three-phase AC 50/60HZ, maximum voltage 660V, 3150A system rated current and three-phase four-wire and three-phase five-wire, widely used in power plants, substations, industrial and mining enterprises, hotels, airports, docks And the construction,...

Description

GCK type low voltage switchgear is suitable for three-phase AC 50/60HZ, maximum voltage 660V, 3150A system rated current and three-phase four-wire and three-phase five-wire, widely used in power plants, substations, industrial and mining enterprises, hotels, airports, docks And the construction, transmission and distribution of broadcasting and communication centers, as well as power conversion, power distribution and power consumption in PC and motor control center MCC


The 440V low voltage MCC motor control panel is used for motor control to start or stop the motor.

Take 400A MCCB as the main circuit breaker, three-phase No. 3 ampere meter, which is used to indicate the total current of all drawer modules.

1 x 95 KW/250A drawer type modular control, start the motor through star delta. 3 x 15KW/50A and 3 x 7.5KW/32A modular direct start motors.

In each unit inside, MCCB is installed as the main switch, thermal overload relay and AC contactor

Two medium-sized relays are additionally equipped inside, one relay with a coil 24VDC for receiving signals from the PLC, and the other relay for opening/closing the scene


Use scope and purpose

Switchboards are used in power distribution systems in power plants, high-rise buildings, chemical industries, and petroleum, metallurgical and textile industries. It is used as a complete low-voltage power distribution equipment in large power plants that need to be connected to computers and highly automated petroleum and chemical industries for power distribution in power generation and distribution systems with a three-phase AC frequency of 50 (60) . ) Hz, 380V (400) (600) and rated current, maximum and below (including 4000A), as well as centralized motor control and reactive power compensation.


Conditions of Use of Electrical panels

Ambient temperature: -15'C~+40'C

Altitude: <= 1000m

Air humidity: daily average of air humidity <= 95%, daily average of partial vapor pressure <= 2.2kPa; monthly average air humidity <= 90%, monthly average partial vapor pressure <= 1.8kPa

Earthquake intensity <= 8 degrees

No corrosive or flammable gas

Special circumstances depend on the user


3 phase switchgear

ItemUnitParameters
Rated voltageKV3, 7.2, 12
Rated currentA630,1250,1600,2500,3150,4000*
Rated short circuit breaking currentKA25, 31.5, 40
Rated short circuit switching current63, 80, 100
Rated short-yime withstand current(4s)25, 31.5, 40
Rated peak withstand current63, 80, 100
Rated frequency
Hz50
Rated insulation level1 min power frequency withstand voltageKV42
Lighting impulse withstand voltage75
control circuit voltagesACV110, 220, 380
DCV110, 220
Protection degree
Housing IP4X , cubicle and circuit breaker IP2X when door is open


Order information


Schematic diagram of main circuit or electrical schematic diagram

Arrangement and layout

Model, specification and quantity of main components.

Incoming and outgoing wire method and cable specification, etc

If bus connection is required between the devices, bus connection and height from the ground shall be provided.

Hot Tags: Metal Clad Low Voltage Switchgear, China, manufacturers, suppliers, customized, indoor Distribution Cabinet, Indoor Low Voltage Switchgear, lv power distribution cabinet, Low voltage electrical switch Cabinet, 3 phase switchgear, low voltage outdoor switchgear

(0/10)

clearall