Low Voltage Switchgear Switchboard
MNS switchgear is suitable for power plants, substations, petrochemical plants, metallurgical steel rolling, transportation power, light industrial textiles and other factories, mining enterprises and residential communities, high-rise buildings and other places. It is used for power conversion, distribution and control of power distribution equipment in power systems with AC 50-60Hz and rated working voltage AC 660V and below.
Description
Low Voltage Switchgear Switchboard
MNS switchgear is suitable for power plants, substations, petrochemical plants, metallurgical steel rolling, transportation power, light industrial textiles and other factories, mining enterprises and residential communities, high-rise buildings and other places. It is used for power conversion, distribution and control of power distribution equipment in power systems with AC 50-60Hz and rated working voltage AC 660V and below.
Technical parameter
Item | Unit | Value | ||
1 | Rated working voltage of main circuit (AC) | V | 380 660 | |
2 | Rated insulation voltage of main circuit (AC) | V | 660 | |
3 | Rated frequency | HZ | 50 | |
4 | Rated bus current | Horizontal bus | A | 1600 2500 3150 4000 5000 |
Vertical bus | A | 1000 2000 | ||
5 | Rated short-time withstand current (1S) | Horizontal bus | KA | 50 80 |
Vertical bus | KA | 50 | ||
Protective conductor | KA | 30 48 | ||
Neutral bus | KA | 30 48 | ||
6 | Rated peak withstand current | Horizontal bus | KA | 105 176 |
Vertical bus | KA | 105 | ||
7 | Degree of protection of the shell | IP30 IP40 | ||
Use environmental conditions
1. The air temperature around MNS low-voltage switchgear: not higher than +40℃, not lower than -5℃, and its average temperature within 24 hours is not higher than +35℃;
2. The relative humidity of the air around the MNS switchgear: the air is clean, the relative humidity does not exceed 50% when the maximum temperature is +40℃, and higher relative humidity is allowed at lower temperatures, for example, 90% at +20℃;
3. Installation altitude: no more than 2000 meters;
4. The installation inclination of the switch cabinet: not more than 5 degrees;
5. There is no place where there is violent vibration, explosive gas, chemical corrosive gas and dust that can destroy insulation around the switchgear;
6. The withdrawable switchgear is suitable for transportation and storage in the following temperature range: -25°C to +55°C, not exceeding +70°C in a short time (24 hours).



Factory


Certificates

Contact us:
Contact: Charles Du
Mobile: +86 18639199897
E-mail: Fengyuan800@outlook.com
If you want to know more about our products, please contact us. Looking forward to serving you.
Hot Tags: low voltage switchgear switchboard, China, manufacturers, suppliers, customized, indoor Distribution Cabinet, Electrical Panel Board, MNS Low Pressure Draw out Switch Cabinet, GGD type metal low voltage switchgear, lv power distribution cabinet, distribution board