GCS Electric Distribution Switch Power Cabinet
GCS drawer cabinet is an advanced product developed by integrating the advantages of other low-voltage products. It is suitable for power distribution systems in power plants, petrochemicals, metallurgy, telecommunications, light industry, textiles, high-rise buildings and other civil,...
Description
GCS Electric Distribution Switch Power Cabinet
GCS drawer cabinet is an advanced product developed by integrating the advantages of other low-voltage products. It is suitable for power distribution systems in power plants, petrochemicals, metallurgy, telecommunications, light industry, textiles, high-rise buildings and other civil, industrial and mining enterprises. Large-scale power plants, petrochemical, telecommunications systems, etc., have a high degree of automation and require computer interfaces, as low-voltage power distribution devices for centralized control of distribution motors and reactive power compensation in power generation and power supply systems. The product has good breaking capacity, good dynamic and thermal stability, flexible electrical scheme, convenient combination, strong serial applicability, novel structure, and high protection level.
Service environment
a) Air temperature: Maximum temperature: +40°C; Minimum temperature:-15°C
b) Humidity: Monthly average humidity 95%; Daily average humidity 90% .
c) Altitude above sea level: Maximum installation altitude: 1000M.
d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
e) No frequent violent shake
The main parameters:
1. Rated voltage of main circuit: AC 400V, 690V
2. Rated voltage of auxiliary circuit: DC 110V, 220V
3. Rated frequency: 50HZ
4. Rated insulation voltage: 690V
5. Rated current: horizontal busbar <4000A
6. Vertical bus: 1000MCC
7. Busbar rated short-time withstand current: 50kA/1s, 80kA/1s
8. Busbar rated peak withstand current: 105kA/0.1s, 176kA/0.1s
9. Power frequency test voltage: 2500V/min
10. Auxiliary circuit: 1760V/min
11. Protection level: IP30, IP40
Parameter | ||||
Rated voltage | V | 400 | 690 | |
Rated insulation voltage | V | 690 | 1140 | |
Rated impact withstand voltage | V | 6000 | 10000 | |
Rated working short circuit breaking ability | kA | 18~100 | 10~75 | |
Rated utmost short circuit breaking ability | kA | 25~120 | 20~85 | |
Rated frequency | Hz | 50/60 | ||
Rated current | A | 400,500,630,800,1000,1250,1600,2000,2500,3150,4000,5000,6300 | ||
Rated control power | V | AC 110/220/380,DC 110/220 | ||
Dimension (Unit:mm) | MNS/GCS/GGD | width | 400,600,800,1000,1200 | |
depth | 600,800,1000 | |||
height | 2200 | |||
Low voltage drawer type switchgear is favored by many power engineering customers due to its advantages such as convenient maintenance, multiple group outgoing circuits, and small footprint. Although there are many manufacturers in the field, there are varying levels of technical expertise and production volume. Many small and medium-sized switch factories, due to their weak technical foundation, do not have a grasp of the specifications and standards related to the machinery and equipment in the distribution room. There are risks in the design and installation of drawer cabinets and switch cabinets, coupled with poor customer operation and maintenance management, and the aging of components in the cabinets due to increased operating time, This will lead to a high incidence of high-voltage switchgear accidents and even major accidents such as burning damage
Common fault causes
The temperature inside the cabinet is too high. Long term load operation, long-term current carrying capacity of conductors, and lack of maintenance and upkeep of the cabinet body, resulting in severe ash in the cabinet volume, overall poor heat removal, no dehumidification or air conditioning temperature reduction equipment in the distribution room, and high temperature operation of the power switch itself and transmission lines, resulting in reduced overall characteristics and reduced service life. Aging of machinery, equipment, and routes. Due to the lack of power outage inspection standards in operation and long-term operation, key components have not been immediately maintained, inspected, or replaced, accelerating the aging of machinery, equipment, and routes, and reducing their lifespan.
Response measures
The incoming and outgoing conductors in the drawer cabinet should use reliable cable cables or grounding copper bars containing insulation layer heat shrink sleeves, and be installed in accordance with relevant national industry standards; The power distribution room should enable the opening of equipment monitoring system software for easy reading and viewing of machine equipment operation. Perform data analysis on historical records and compare specific operational data information to immediately detect anomalies and prevent them from occurring. At the same time, the distribution room should enhance the management methods of the ventilation system, and the output power and efficiency of the ventilation system should meet the requirements of normal operation; The operating bottom pressure cabinet in the distribution room should undergo quality inspection on time, mainly for key components such as internal power switches, copper transmission lines, connectors, etc., which need to be disassembled and replaced when necessary.
The required loads in the distribution room should be managed in a standardized manner and labeled one by one. For very critical and critical loads, protective equipment should be enhanced, and targeted inspection plans should be formulated and executed in a floor mounted manner; Timely conduct reasonable technical training for institutional operation and maintenance management staff and distribution room managers, such as research and training on knowledge of distribution room operation and maintenance management, emergency response to sudden abnormalities, prevention, and other topics. Conduct emergency plan drills and practical operation evaluations on time, and enhance the skill level of staff and communication ability to solve emergency problems in multiple aspects.
summary
Low voltage drawer cabinets are key distribution equipment for the bottom pressure system software in the distribution room. According to accident expectations, high-voltage switchgear manufacturers attach great importance to them and should strictly follow national industry standards for design, production, and installation. As power engineering customers, they should also carry out regular maintenance, upkeep, and upkeep of the machinery and equipment to ensure their normal operation together.
PRODUCT PHOTO












Conditions of Use:
1. For indoor use, the altitude of the point of use shall not exceed 2000m.
2. The ambient air temperature is not higher than +40 degrees and not lower than minus 5 degrees. And the average temperature within 24 hours shall not be higher than +35 degrees. When it exceeds, the capacity should be reduced and run according to the actual situation.
3. The relative high temperature of the surrounding air is +40 degrees and not more than 50%, and a larger relative temperature is allowed at a lower temperature; if +20 degrees is 90%, it should be considered that the temperature change may occasionally cause condensation .
4. When the device is installed, the tilt should not exceed 5° from the vertical plane, and the entire group of cabinets should be relatively flat and conform to the (GBJ232-2) standard.
5. The device should be installed in a place where there is no severe vibration and impact, and the electrical components are not enough to be used and there should be no corrosion
FACTORY WORKSHOP

PACKING&DELIVERY


Order information:
Main circuit schematic diagram or electrical schematic diagram
Arrangement and layout
The model, specification and quantity of the main components.
Way of incoming and outgoing wires, cable specifications, etc.
If a bus connection is required between devices, the bus connection and the height from the ground should be provided
Our services:
1,Quick response in before sales period help you got order
2,Excellent service in production time let you know each step we made
3,Reliable quality solve you aftersale headache
4,Long quality waranty ensure you can buy without hesitate
FAQ
Q5 : Is OEM/ODM available?
A: Yes, it is! Our products can be Customized. We have design and engineer teams,we can customize products according to customers' drawing or requirements.
Q6 : You are manufacturer or trading company?
A: We are factory, As a 100% professional manufacturer with 20 year's manufacturer experience, we could produce products according to customers' requirements and we could also control the quality of products 100%.
Q7 : Can the price be negotiated?
A: Yes, the price is negotiable. It can be changed according to your quantity or package
Q8 : How about inspection?
A: We have the whole inspection system from raw material to end products include temperature rise test,salt spraying test conductor type test,mechanical life test.
Q9 : What is payment terms?
A: T.T, Paypal,Western Union,Alibaba trade assurance and L/C is acceptable. 30% T/T in advance ,70% balance before shipment.
Q10 : What is the service offered by company?
A: We have the professional engineer team which can design and develop the mold to arrive different customer requirement.
We also have the sales team to offer good service from pre-sale to after-sale.
This product is usually customized.
We are a manufacturer and have a professional technical department that can design and provide solutions according to customer needs.
Please contact our sales personnel to obtain design drawings
Here are our customer examples for your reference
Nepalese clients
| 2 pcs of LV switchgear and 1 ATS panel | ||
| his time it is with 9 withdrawables | ||
| We request you to kindly provide us the Quotation with BOM List with your best price offer for the GCS LV withdrawable Switchgear and the Automatic Transfer Switch (ATS Panel) as per the specification listed below. The Quotation should be valid for 120 days. | ||
| GCS LV Withdrawable Switchgear | ||
| S.N. | Specifications | Yes/No/If any |
| Electrical Panel (Low-voltage withdrawable switchgear cabinet) | ||
| Manufacturer | ||
| Brand | ||
| Type/Model | GCS | |
| Country of Origin | ||
| 1 | Description of Function | |
| 1.1 | It is group of low voltage switchgear withdrawable cabinet that can be operated easily and safely. | |
| 2 | Operational Requirements | |
| 2.1 | Electrical supply can be disconnected manually and automatically during overload and short-circuit. | |
| 3 | System configuration | |
| 3.1 | Low voltage switchgear withdrawable cabinet with all the essential components and copper busbar | |
| 4 | Technical Specifications | Ratings |
| 4.1 | Main circuit rated voltage | 400V |
| 4.2 | Rated frequency | 50Hz |
| 4.3 | Rated insultation voltage | 690V (1000V) |
| 4.4 | Maximum working current of main busbar (copper) | 1000A |
| 4.5 | Rated withstand current of main busbar | 100KA/1s |
| 4.6 | Protection Level | IP40 |
| 4.7 | Operating Mode | Manual and Automatic |
| 4.8 | Metal drawer type | 8E or 16E or Equivalent |
| 4.8.1 | 400A Drawer | 1 No. |
| 4.8.2 | 300A Drawer | 1 No. |
| 4.8.3 | 250A Drawer | 1 No. |
| 4.8.4 | 200A Drawer | 2 No. |
| 4.8.5 | 150A Drawer | 2 No. |
| 4.8.6 | 100A Drawer | 2 No. |
| 4.9 | Outer Dimension | Approx. (80cm X 105cm X 220cm) |
| 4.10 | Each drawer must have 3-digital or analog ammeter to measure 3-phase (R-Y-B) current individually | |
| 4.11 | Busbar must be of copper three phase four wire with protective Earthing (R,Y,B,N,PE). | |
| 4.12 | The MCCB should be of high quality & sensitive | |
| 4.13 | The operating mechanism of the drawers must be easy and smooth. | |
| 4.14 | Drawer Handle must be highly insulated and strong | |
| 4.15 | The outer dimension should approx match to (80cm X 105cm X 220cm) | |
| 4.16 | The outer design and color should match as per the design as shown in picture | |
| 5 | Busbar Tray | |
| 5.1 | The busbar tray must be installed at the top of the compartment of the functional unit, and the connection line and the common power lne can be put in the tray | |
| 5.2 | The required number of Busbar should be connected from existing system to installed cabinet by nut-bolt/ Busbar trunking system as per requirement | |
| 6 | Accessories, spares and consumables | |
IF NEED MORE DETAILES,PLEASE FEEL FREE YO CONTACT US