Vb4p/S-10kv/630A-31.5ka Lateral Type Indoor Vacuum Circuit Breaker (indoor vcb)
Indoor AC high voltage vacuum circuit breaker hereinafter referred to as a circuit breaker is a three-phase AC rated voltage indoor switchgear, which can be used for the control and protection of electrical facilities in industrial and mining enterprises, power plants and substations, and is...
Description
Our overarching strategic focus is to become one of the most influential brands of manufacturing Solid Insulated Ring Main Unit rmu, Distribution Transformer, AC Switch Cabinet in the marketplace. We are always willing to provide sincere and thorough service for our customers in the future. We regard respecting knowledge and valuing talents as our strategic policy for sustainable and stable development of the company. If the customer provides their own designs, We will guarantee that they will likely be the only one can have that merchandise. Opening up is a platform for rapid development. Under the background of economic globalization, our company is committed to providing first-class products and services to global customers.
Indoor AC high voltage vacuum circuit breaker hereinafter referred to as a circuit breaker is a three-phase AC rated voltage indoor switchgear, which can be used for the control and protection of electrical facilities in industrial and mining enterprises, power plants and substations, and is suitable for places with frequent operations.
The circuit breaker meets the standard requirements of "AC high voltage circuit breaker", 855-1996 "3.6-40.5kV indoor AC high voltage vacuum circuit breaker", DL403-91, "10-35KV indoor AC high voltage circuit breaker ordering technical requirements", and meets The relevant requirements of IEC56 (Publication 87).
The circuit breaker adopts an integrated design of the operating mechanism and the circuit breaker body, which can be used as a fixed installation unit or a dedicated propulsion mechanism to form a handcart unit.
It is an indoor switchgear with three-phase AC 50Hz rated voltage of 12KV power system. It is used as protection and control unit for power equipment and industrial and mining enterprises. Applicable to places that require frequent operation at rated operating current, or multiple times to break short-circuit current.
The circuit breaker adopts an integrated design of the operating mechanism and the circuit breaker body, and can be used as a fixed installation unit, or can be equipped with a special propulsion mechanism to form a hand truck unit.
Features: small size, light weight, suitable for frequent operation
Main structure: vacuum interrupter, electromagnetic or spring operating mechanism, bracket and other components.
Conditions of use:
The ambient temperature is not higher than +40℃, not lower than -15℃ (storage and transportation allowed at -30℃);
The altitude does not exceed 1000m;
Relative temperature: the daily average value is not more than 95%, the monthly average value is not more than 90%, the daily average value of saturated vapor pressure is not more than 2.2×10Mpa, and the average value is not more than 1.8×10 MPa;
The earthquake heat does not exceed 8 degrees;
There is no place with fire, explosion hazard, serious pollution, chemical corrosion and severe vibration.
The main technical parameters:
NO | Item | Units | Technical parameters | ||
1 | Rated voltage | KV | 12 | ||
2 | Rated short-duration power frequency withstand voltage | 42/48(Interphase, ground/fracture) | |||
3 | Rated lightning impulse withstand voltage | 42/48(Interphase, ground/fracture) | |||
4 | Rated frequency | Hz | 50 | ||
5 | Rated current | A | 630 1250 | 630 1250 1600 2000 2500 3150 | 630 1250 1600 2000 2500 3150 |
6 | Rated short-circuit breaking current | KA | 20/25 | 31.5 | 40 |
7 | Rated short-time withstand voltage | 20/25 | 31.5 | 40 | |
8 | Rated short circuit duration | S | 4 | ||
9 | Rated peak withstand current | KA | 50/63 | 80 | 100 |
10 | Rated short circuit closing current | 50/63 | 80 | 100 | |
11 | Secondary circuit power frequency withstand voltage (1min) |
2000 | |||
12 | Rated single / back to back capacitor group breaking current | A | 630/400(40kA:800/400) | ||
13 | Rated capacitor bank closing current | 12.5 (frequency is not greater than) | |||
14 | Mechanical life | KA | 20000 | ||
15 | Rated current breaking times (electrical life) | 20000 | |||
16 | Rated short circuit current breaking times | times | 50(40KA≤30) | ||
17 | Dynamic and static contacts allow wear cumulative thickness | mm | 3 | ||
18 | Energy storage time | s | ≤10 | ||
19 | Contact opening distance | mm
| 11±1 | ||
20 | Overtravel | 3.5±0.5 | |||
21 | Contact closing bounce time | ms
| ≤2(40KA≤3) | ||
22 | Three-phase split/closed period | ≤2 | |||
23 | Average opening speed (contacts are separated by -8mm) | m/s
| 1.2±0.2 | ||
24 | Main conductive loop resistance | 0.6±0.2 | |||
25 | Main conductive loop resistance | μΩ | ≤50(630A)≤45(1250A) ≤40 (1600,2000A)≤35 (2500A or more) | ||
26 | Rated operation sequence | 0-0.3s-Co-180s-Co | |||
Fields of application:
The following is a list of SM6 range units used in medium/low voltage substations and industrial distribution substations:
Cable control and protection
Overhead control and protection
Transformers and distribution substations
Motor and transformer control and protection
Generator control and protection
Control and protection of capacitor bank
PRODUCT PHOTO






FACTORY

FAQ:
Q1: If I am interested in your products, when can I receive your quotation and detailed information after sending the inquiry?
A: All your queries will be answered within 24 hours.
Q2: Because I cannot confirm the quality of your products, can I get samples before ordering?
A: Of course! We also believe that sample ordering is the best way to build trust. In our company, we provide sample service! Please send inquiries to us and get samples!
Q3: Do you have a catalog? Can you send me a catalog to check all your products?
A: Yes, we have a product catalog. Please contact us online or send an email to send the catalog.
Q4: I need a price list of all your products. Do you have a price list?
A: We do not have a price list for all products. Because we have a lot of products, it is impossible to mark all prices on the list. Due to production costs, prices are always changing. If you want to check any prices of our products, please feel free to contact us. We will send you a quote as soon as possible!
This product is usually customized.
We are a manufacturer and have a professional technical department that can design and provide solutions according to customer needs.
Please contact our sales personnel to obtain design drawings
Here are our customer examples for your reference
IF NEED MORE DETAILES,PLEASE FEEL FREE YO CONTACT US
We have always insisted on forging ahead, pioneering and innovating, and working hard to eventually become a leading enterprise in Vb4p/S-10kv/630A-31.5ka Lateral Type Indoor Vacuum Circuit Breaker (indoor vcb) industry. After years of development, our company occupies a leading edge in the market, with business covering many countries and regions around the world. Our pursuit and firm aim should be to 'Always fulfill our buyer requirements'.
Hot Tags: vacuum circuit breaker for indoor type with handcart, China, manufacturers, suppliers, customized, European prefabricated substations, SF6 insulated switchgear general electric, SF6 Insulated Switchgear, lv power distribution cabinet, Metal-Enclosed Switchgear, fully insulated compact switchgear
[[ProKeywords]]Send Inquiry
You Might Also Like
-

Cast Resin Dry Type Transformer up to 38.5kv
-

Hot Sale Indoor Use High-Voltage Switchgear Hxgn-40.5
-

40.5 Kv Indoor High Voltage Vacuum Circuit Breaker/3...
-

24kv Gas Insulated High Voltage Electrical Switchgear
-

Power Electrical Compact Distribution Prefabricated ...
-

Fast-Breaking Sf6 Gas Insulatied Switchgear Ring Mai...