Manufacturers Direct Ybw Outdoor Box Substation Customized Integrated Pre-Installed European Box Substation
Pre-installed Transformer Substation description AC metal closed type shift switch cabinet is a three-phase AC 50HZ indoor device metal-enclosed switchgear, used in power plants and substation systems with a rated voltage of 35kV, a rated maximum current of 2000A, and a single bus or section...
Description
Our focus on should be to consolidate and enhance the quality and repair of present products, in the meantime constantly establish new products to meet unique customers' requires for intelligent compact ring main unit, 40.5kV High Voltage Vacuum Circuit Breaker, oil-immersed transformer. Our company actively advocates and strives to practice the modern enterprise management concept. We are people-oriented and strive to build a modern enterprise with advanced technology, scientific management, prosperous career and first-class talents. We work with our friends with first-class products and sincere services to advance to the depth and breadth of the international market. We got best suppliers support on quality and price.
Pre-installed Transformer Substation description
AC metal closed type shift switch cabinet is a three-phase AC 50HZ indoor device metal-enclosed switchgear, used in power plants and substation systems with a rated voltage of 35kV, a rated maximum current of 2000A, and a single bus or section with a maximum voltage of not more than 40.5kV Busbar sets of power distribution equipment.
The switchgear meets the requirements of DL/t404-91, IEC298, GB3906 and other standards, and has the functions of preventing misoperation of the circuit breaker, pushing the trolley with load, grounding wire, power transmission with grounding wire and accidental charging. Interval (called "five preventive measures").
Box-type substations are suitable for residential areas, urban public transformers, prosperous urban areas, and building electricity. Users can choose box type changes according to the conditions of use and load level. Since the advent of the box-type substation, it has developed rapidly. In developed countries, 70% of distribution transformers have been developed, while the United States has accounted for 90%. The rapid development of China's urban modernization and the transformation of urban distribution networks will be widely used.
Box-type substations are used in high-rise residential buildings, luxury villas, square parks, residential areas, small and medium-sized factories, mines, oil fields and temporary buildings to receive and distribute electricity in the power distribution system.



Main technical parameters | |||
HV unit | Rated frequency | Hz | 50 |
Rated voltage | kV | 7.2 12 24 40.5 | |
Rated current of main bus | A | 630 1250 1600 | |
Rated short-time withstand current / duration | kA/s | 20/4 25/3 31.5/4 | |
Rated peak withstand current | kA | 50 63 80 | |
1min power frequency withstand voltage (to-ground/between open contacts) | kV | 32/36 42/48 65/79 95/115 | |
Lightning impulse withstand voltage (to-ground/between open contacts) | kV | 60/70 75/85 125/145 185/215 | |
Rated short-circuit breaking current | kA | 20 25 31.5 | |
Ground loop short-time withstand current / duration | kA/s | 20/2 20/4 | |
Rated short-circuit making current of main loop | kA | 50 63 80 | |
Rated active load breaking current | A | 630 | |
Rated closed loop breaking current | A | 630 | |
Rated transfer current | A | 1700 | |
Mechanical life peroid | times | 3000 5000 10000 | |
LV unit | Rated frequency | Hz | 50 |
Rated voltage | kV | 0.4/0.23 | |
Rated insulation voltage | V | 690 | |
Rated current of main loop | A | 100~3200 | |
Rated short-time withstand current | kA/s | 30/1 50/1 100/1 | |
Rated peak withstand current | kA | 63 105 176 | |
5s power frequency withstand voltage | kV | 2.5 3.75 | |
Transformer unit | Rated frequency | Hz | 50 |
Rated voltage | kV | 7.2 12 24 40.5/0.4 | |
Rated capacity | kVA | 30~1600 | |
1min power frequency withstand voltage | kV | 25/20 35/28 55/50 85/75 | |
Lightning impulse withstand voltage | kV | 60 75 125 170 | |
Impedance voltage | % | 4~6 | |
Tapping range | ... | ±×2.5% ±×5% | |
Connection group | ... | Y,yn0 D,yn11 | |
Type | ... | Oil-immersed type, dry type | |
Cabinet body | IP code of HV and LV chambers | ... | IP33D |
IP code of transformer chamber | ... | IP23D | |
Sound level (oil-immersed type/dry type) | dB | ≤50/55 | |

Please just contact us if you need
We know that we only thrive if we can guarantee our combined rate competiveness and good quality advantageous at the same time for Manufacturers Direct Ybw Outdoor Box Substation Customized Integrated Pre-Installed European Box Substation. With strict inspection systems, complete production processes, advanced process equipment, and scientific management system, each product can meet customer requirements! We always insist on starting from the needs of customers, focusing on customer requirements and ideas, and design and manufacture each product with a professional perspective. We create great convenience and benefits for you.
Hot Tags: pre-installed transformer substation, China, manufacturers, suppliers, customized, Electrical Ring Main Unit, insulated switchgear ring main unit, Withdrawable Power Distribution Switchgear Panel, Pole-mounted transformers, high voltage switch equipment, fixed metal enclosed switchgear
[[ProKeywords]]Send Inquiry
You Might Also Like
-

11/0.4kv 33/0.4kv 25kVA ~2500kVA Oil Immersed Power ...
-