3.6-40.5kV Environmental Protection Outdoor Prefabricated Electric Substation
Prefabricated transformer substation is a compact substation which combines high voltage switch system,low voltage distribution panel,distribution transformer,electric energy calculation part and power compensation device. Service condition 1. Altitude: ≤1000m (above sea level) 2. Ambient...
Description
Due to the wide application of our products and our favorable market position, we strive to sell our Electrical switchgear cabinet, metal enclosed low voltage switchgear, switching station to more countries and bring our high-quality products and services to every corner of the world. We continue to actively explore to make the system and management of the company more perfect, and set up a strict and effective production, sales, service and research and development system. We have a deep understanding of the meaning of 'customer-oriented', and will 'service' throughout every detail of the company's operation and management, so as to win extensive trust and support from customers.
Outdoor Box Type Prefabricated Combined Substation
Prefabricated transformer substation is a compact substation which combines high voltage switch system,low voltage distribution panel,distribution transformer,electric energy calculation part and power compensation device.
Service condition
1. Altitude: ≤1000m (above sea level)
2. Ambient temperature: highest and lowest 40C -25℃
The highest monthly average temperature: ≤35C
The highest annual average temperature: ≤25C
3. Relative humidity: daily average ≤95%, monthly average ≤90%
4. Maximum daily temperature difference: 25℃
5. Intensity of sunshine: 0.1W/CM2 (wind speed 0.5M/S);
6. Outdoor wind speed: ≤35m/s;
7. Pollution level: level three;
8. Rainproof grade: level 3;
9. The slope of the installation site should not be greater than 3°;
10. Seismic resistance: the ground horizontal acceleration is 0.2g
The ground vertical acceleration is 0.1g;
11. Installation site: There should be no fire/explosion hazard/severe pollution/chemical substances
Corrosion and subtle vibrations.
If the service conditions are different from the above conditions, the customer should negotiate with the manufacturer.
Feature
1. The frame of the substation is made of anticorrosive grooved steel and angle steel, so it is tough enough in terms of machinery and rigidity.
2. The shell material can be cold rolled steel plate, stainless steel plate, aluminum alloy plate, composite color plate.
3. The small rooms of the substation are divided into separate small rooms by steel plates. The small rooms can be arranged in various forms such as the Chinese characters "eye" and "level".
4. In order to facilitate monitoring and maintenance, the transformer room, high voltage room and low voltage room are all equipped with lighting devices.
5. The substation cover is designed with two layers to prevent heat radiation and increase the indoor temperature.
6. The transformer mainly uses natural ventilation. When the temperature exceeds the set value, the axial fan on the top will automatically start to control the room temperature of the transformer.
7. All rotating connecting parts are equipped with sealing devices, which have good moisture resistance.
8. Perfect protection performance, convenient operation, and perfect "five prevention" functions on the high-pressure side to ensure safe maintenance.
9. Compact structure, beautiful appearance, can be used in conjunction with the surrounding environment.





| Items | Unit | Parameters | ||
| HV Unit | Rated Voltage | kV | 12 | |
| Rated Frequency | Hz | 50 | ||
| Rated Main Busbar Current | A | 630 | ||
| 1min Power Frequency Withstand Voltage To Earth, Between Phases/to open gap | kV | 42/48 | ||
| Lightning Impulse Withstand Voltage to Earth and Between Phases/ to open gap | kV | 75/85 | ||
| Rated Short-time Withstand Current | kA/s | 25/2 | ||
| Rated Peak Withstand Current | kA | 63 | ||
| Rated Short-time Making Current | kA | 50 | ||
| Fuse Breaking Current | kA | 31.5/40 | ||
| LV Unit | Rated Voltage | V | 400 | |
| Main Circuit Rated Current | A | 100~4000 | ||
| Rated Limit Short-circuit Breaking Capacity | kA | 80 | ||
| Rated Operating Short-circuit Breaking Capacity | kA | 50(65) | ||
| Rated Short-time Withstand Current | kA/1s | 50(65) | ||
| Branch Current, Compensation Capacity | According to users’ requirements | |||
| Transformer Unit | Rated Capacity | kVA | 30~2000 | |
| Resistance Voltage | % | 4/ 4.5 | ||
| Tapping Range | % | ±2X2.5; ±5 | ||
| Connected Group | Y,yn0; D,yn11 | |||
| Case | Protection Level | IP23 | ||
| Sound Level | dB | ≤50 | ||
WORKSHOP


CERTIFICATE




EXHIBITION

COMPANY OVERVIEW

FAQ
Q5 : Is OEM/ODM available?
A: Yes, it is! Our products can be Customized. We have design and engineer teams,we can customize products according to customers' drawing or requirements.
Q6 : You are manufacturer or trading company?
A: We are factory, As a 100% professional manufacturer with 20 year's manufacturer experience, we could produce products according to customers' requirements and we could also control the quality of products 100%.
Q7 : Can the price be negotiated?
A: Yes, the price is negotiable. It can be changed according to your quantity or package
Q8 : How about inspection?
A: We have the whole inspection system from raw material to end products include temperature rise test,salt spraying test conductor type test,mechanical life test.
Q9 : What is payment terms?
A: T.T, Paypal,Western Union,Alibaba trade assurance and L/C is acceptable. 30% T/T in advance ,70% balance before shipment.
MORE VIDEO
https://www.facebook.com/bob.niu.35/
Youtube
www.youtube.com/channel/UC5IP4dL0UTQG4fgAOa3UhWA
https://twitter.com/FengyuanE
Ordering instruction:
1. Conceptual drawing or electrical schematic diagram of main circuit.
2. Model, specification and quantity of main components.
3. Incoming and outgoing line mode and cable specification, etc.
4. Shell material and appearance: composite plate, steel plate, stainless steel plate, cement plate, etc.
5. Other order requirements.
Welcome to inquiry
Contact information:
Jiyuan Fengyuan Electrical Equipment Co., Ltd
Sales Department
Contact person:Mr Charles Du
E-mail:fengyuan800@outlook.com
Mobile:+8618639199897(Available for whatsapp,wechat,skype)
Add:Huling industrial zone,jiyuancity,henan province,China
TEL:+86-0391-2180800
FAX:+86-0391-2180818
With an international vision and global service capabilities, we strive to provide customers with cost-effective 3.6-40.5kV Environmental Protection Outdoor Prefabricated Electric Substation products. With our faith, we are to create fortune for you. The company has achieved considerable development through continuous investment in R&D and innovation as well as a series of innovative technology projects in the field of industrial development.
Hot Tags: Outdoor Box Type Prefabricated Combined Substation, China, manufacturers, suppliers, customized, Oil Immersed Type Transformers, rmu unit electrical, outdoor vcb breaker, 12kv Medium Voltage Switchgear, High Efficiency Oil Type Distribution Transformer, electrical switchgear