200kVA 13.2kv 13.8kv Oil Filled Three Phases Power Distribution Transformer/ Power Transformer
Low loss 3 phase distribution transformer is an electrical appliance which uses insulating oil as insulating medium and is composed of iron core, coil, voltage regulating switch, oil tank, etc. to change the voltage and transmit AC energy.
Description
Our company insists all along the quality policy of 'product good quality is base of enterprise survival; buyer fulfillment will be the staring point and ending of an company; persistent improvement is eternal pursuit of staff' and also the consistent purpose of 'reputation very first, shopper first' for combined switch cabinet, Gas Insulated Switchgear Panel, distribution board. We try our best to provide our customers with better products and the most complete services based on the forefront of modern development, relying on science and technology and courage to explore, and has become one of the most competitive enterprises in the same industry in China. Since the establishment of our company, we have strictly followed the standard operation of modern enterprise management mechanism, and our products have excellent quality and enjoy a high reputation at home and abroad.
3 Phase Oil Filled Transformer
Product description:
3 Phase oil filled Transformer is an electrical appliance which uses insulating oil as insulating medium and is composed of iron core, coil, voltage regulating switch, oil tank, etc. to change the voltage and transmit AC energy.
Our company has rich product series, including laminated iron core series, amorphous alloy series and other products under 35kV.
1.Oil immersed transformer, also known as oil immersed transformer, is a transformer device that uses oil cooling to reduce the temperature of the transformer. Unlike dry transformers, the main body of an oil immersed transformer is installed in a welded steel oil tank filled with insulating oil. When an oil immersed transformer is in operation, the heat from the coil and iron core is first converted into insulating oil and then into cooling medium. According to the capacity, it can be divided into immersed Free cooling transformer and immersed forced air cooling transformer.
2、 The structure and working principle of oil immersed transformers
Oil immersed transformers are structurally similar to transformers It is one of the types of transformers classified according to the insulation form of the iron core. Therefore, it has recognizable features of oil immersed coils, which can reduce the heat map of the equipment inside.
The basic components of the oil immersed type are composed of magnetic cores, windings, and bushings. The magnetic core provides a path for magnetic flux. The winding creates a magnetic field consisting of a conductor coil wound around an iron core and insulated with a cardboard barrier and shielding layer. The thickness of the winding insulation layer increases with increasing voltage. The bushing connects the transformer winding to the substation.
Oil type transformers are used for power distribution or substations. Their core and coils are immersed in oil, which can cool and insulate. Oil circulates through the pipes in the coil and around the coil and iron core components through convection. The oil is cooled externally by the fuel tank at low rated values, and by an air-cooled radiator at high rated values.
3、 Types of oil immersed transformers
There are two main types of oil immersed transformers: single-phase transformer and three-phase transformer.
A. One phase oil immersed transformer
B. Three-phase oil immersed transformer
4、 Purpose of using oil immersed transformers
Oil type transformers can be installed on the ground, base, or pole for outdoor use. They provide efficient performance in various applications, including transmission and distribution networks, renewable energy generation, and small industries.
The oil transformer has a huge capacity, so it will save a lot of electricity, minimize energy loss, save energy, and reduce user costs. Not only that, the oil in the machine can also cool the internal wire cores, thereby improving the durability and electrical performance of transformer equipment.
5、 Precautions for using oil-immersed transformers
1. Oil immersed transformers use oil for operation, so the quality of the oil will significantly affect the lifespan and safety of the transformer.
2. During use, it is necessary to regularly inspect and maintain the transformer system to ensure the normal and safe operation of the machine. Otherwise, there is a high risk of problems and extreme danger.
3. The waste generated by petroleum is prone to polluting the environment and affecting the lives of surrounding people. Therefore, the gradual disposal of waste is also important
Technical parameters:
Rated | Voltage Combination | Winding Connectio Grade | No-load Loss (KW) | Load Loss (KW) | Short | No-load Current | ||
High Voltag (kV) | Tapping Range Of High Voltage | Low Voltage (kV) | ||||||
50 | 0.16 | 1.2 | 1.6 | |||||
100 | 0.23 | 2.01 | 1.4 | |||||
125 | 0.27 | 2.37 | 1.4 | |||||
160 | 0.28 | 2.82 | 1.3 | |||||
200 | 0.34 | 3.32 | 1.2 | |||||
250 | 0.4 | 3.95 | 1.1 | |||||
315 | 0.48 | 4.75 | 1.1 | |||||
400 | 0.58 | 5.74 | 1.0 | |||||
500 | 0.68 | 6.91 | 1.0 | |||||
630 | 0.83 | 7.86 | 6.5 | 0.9 | ||||
800 | 0.98 | 9.4 | 0.8 | |||||
1000 | 1.15 | 11.5 | 0.8 | |||||
1250 | 1.4 | 13.9 | 0.7 | |||||
1600 | 1.69 | 16.6 | 0.6 | |||||
2000 | 1.99 | 19.7 | 0.6 | |||||
2500 | 2.36 | 23.2 | 0.5 | |||||
Widely used:
Low Loss 3 Phase Distribution Transformer widely used in power transmission and distribution system. such as power,transportation,mining, metallurgy ,construction,petrochemical ,communication;
High Reliability Oil Distribution Transformer widely used in urban power network construction and transformation.
Photo:






Main features:
1.Free maintenance.
Low loss, good power saving effect, economic operation, maintenance - free
2.Environmental protection is good.
The high-voltage winding is made of enameled copper wire, while the low-voltage winding is made of copper foil.The windings are poured by imported epoxy resin in the vacuum state. After curing, they form a solid whole with good mechanical strength, small partial discharge and high reliability.
3.Flame retardant explosion-proof.
Flame retardant, explosion-proof, no pollution to the environment, can be installed in the load center.
4.Strong adaptability to the environment.
The coil does not absorb moisture. The core and clamps can operate in 100% relative temperature and other harsh environment after special processing. No dehumidification is required for intermittent operation.
FACTORY PHOTO












Ordering requirements:
1.Type,name, quantity.
2.Technical parameter:
3.Rated capacity.
4.Input&output voltage.
5.No-load loss and load-loss.
6.Any other specical requirements(if any).
This product is usually customized.
We are a manufacturer and have a professional technical department that can design and provide solutions according to customer needs.
Please contact our sales personnel to obtain design drawings
Here are our customer examples for your reference
Togo customer
DESIGNATIONS | UNITS | SPECIFIC DATA | CANDIDATE DATA |
Maker | To be indicated | ||
Reference standard | IEC 60076 | ||
Type | Phase | ||
Vat | Hermetic | ||
Execution | Tropicalized | ||
Dielectric | PCB-free oil | ||
Installation | On pole | ||
Operating ambient temperature | °C | 45 | |
Rated frequency | Hz | 50 | |
Rated power | Kva | 100 | |
Rated primary voltage | Kv | 20 | |
Isolation level assigned to primary school | Kv | 24 | |
Number of phases in primary school | 03 | ||
Secondary voltage | V | 400/230 | |
Voltage adjustment range on the M side when unladen | % | ±2.5 | |
Coupling | DYn11 | ||
Short circuit voltage | % | 4 – 4.5 | |
Neutral sized for one load | % | 100 | |
Maximum vacuum losses | W | 230 - 460 | |
Losses due to Maxi load | W | 1450 - 2350 | |
Maximum steady-state oil temperature | °C | 55 | |
Maximum temperature of the windings in steady state | °C | 60 | |
Winding material | Electrolytic copper | ||
Maximum noise level | Db | 52 | |
50Hz industrial frequency hold, 1 min | Kv | 50 – 70 | |
Shock wave resistance (1.2/50 micros) | Kv | 125 - 170 | |
Cooling | ONAN | ||
Nameplate | 01 | ||
Grounding connection | 01 | ||
Dimensions Height/width/depth | mm x mm x mm | 1200 X 1270 X 820 | |
Total mass of transformer including oil | Kg | 700 | |
Oil mass | Kg | 160 | |
PAINT | |||
§ Tropicalized and anti-rust | |||
Number | § Layers | ||
§ Binder | |||
§ Colour | |||
Plans and technical diagrams to be provided. | |||
IF NEED MORE DETAILES,PLEASE FEEL FREE TO CONTACT US
Our company is committed to becoming a diversified, large-scale and international professional 200kVA 13.2kv 13.8kv Oil Filled Three Phases Power Distribution Transformer/ Power Transformer supplier. We all highly imagine that now we have the full capacity to present you with contented merchandise. We're going to endeavor to maintain our fantastic track record as the very best products supplier in the planet.
Hot Tags: 3 phase oil filled transformer, China, manufacturers, suppliers, customized, fixed metal enclosed switchgear, switchgear insulation products, Gck Low Voltage Draw out Switchgear, Withdrawable Fixed Type Circuit Breaker, high voltage switchgear and control equipment, SF6 insulated switchgear general electric