Unitized Substation
The unitized substation combines high-voltage electrical appliances, transformers, and low-voltage electrical appliances into a compact complete power distribution device, which is suitable for urban high-rise buildings, residential communities, industrial parks, mines and oil fields, as well as...
Description
The unitized substation combines high-voltage electrical appliances, transformers, and low-voltage electrical appliances into a compact complete power distribution device, which is suitable for urban high-rise buildings, residential communities, industrial parks, mines and oil fields, as well as operations and construction. It is used to receive and distribute electrical energy in the power distribution system. The product has the advantages of high performance, compact structure, safe and reliable operation, easy maintenance and mobility.
Compared with ordinary substations of the same capacity, it only occupies 1/10-1/5 of the space, which greatly reduces the workload and cost of design and construction. It is one of the selective complete sets of equipment used for urban and rural construction and reconstruction.
| Item | Units | High-voltage electrical apparatus | Transformer | Low-voltage |
| Rated voltage | kV | 4/10 | 6/0.4 10/0.4 | 0.4 |
| Rated capacity | kVA | 50~1600 | ||
| Rated current | A | 200/400/630 | 100~3200 | |
| Rated short circuit breaking current | A | load switch 400-630 | 15~63kA | |
| kA | The combination switch depends on the fuse | |||
| Rated short time withstand current | kA | 16,20(4s) | 15(1s) | |
| 30(1s) | ||||
| Rated peak withstand current | kA | 31.5,50 | 30 | |
| 63 | ||||
| power frequency withstand voltage(1min) | kV | Opposite and interphase | 25/35(oil type) | ≤0.3,2 |
| 32/42 | ||||
| isolating distance | 20/28(dye type) | >0.3,2.5 | ||
| 36/48 | ||||
| Lightning impact voltage (peak) | kV | Opposite and interphase | 60/75 | |
| 60/75 | ||||
| isolating distance | ||||
| 70/85 | ||||
| Noise level | 55db | |||
| Protection grade | IP23 | |||
| Executive standard | GB/T17467 | |||
| DL/T537 | ||||



Service condition
1. Installation location: outdoor;
2. Altitude: <1000m;
3. The highest ambient temperature: + 40℃;
4. The highest monthly average temperature: + 35℃;
5. The highest annual average temperature: + 20℃;
6. The lowest ambient temperature: -25℃ (outdoor);
7. Maximum daily temperature difference: 25℃;
8. Sunlight intensity: 0.1w/cm2 (wind speed 0.5m/s);
9. Pollution degree: Class III;
10. Rainproof grade: level 3;
11. Relative humidity: the highest monthly average: 90% (20℃); the highest daily average: 95% (20℃);
12. Seismic resistance: ground horizontal acceleration 0.2g; ground vertical acceleration 0.1g;
13. The inclination of the installation site: less than 3 degrees
FAQ:
Q: What's your MOQ(minimum order quantity)?
A: One Set.
Q: Are OEM and ODM available?
A: Yes, it is. Our products can be Customized. we have design and engineer teams, we can customize products
according to customers' drawing or requirements.
Q: What is the quality of your products?
A: Products will be tested qualified before shipment, main components can be customize brand, such as Siemens,Schneider, ABB, etc.
Q: What's your packing methods?
A: Packed in Wooden Case or Carton.As your request.
Hot Tags: unitized substation, China, manufacturers, suppliers, customized, Transformer Substations, compact package kiosk substation, European style substation, substation transmission line, switching station, Electrical Substation