12/0.4KV HV Power Compact Substation
Box type substation is designed as box type and specially for new energy generation industry, which can adjust the low voltage from inverter station to high voltage and then run in power grid. So a box-type inverter station and a step-up station can be integrated into one power generation station. It’s widely applied in Solar Energy Power Plant, Wind Energy Power Plant and Nuclear Power Plant, etc. The products comply with IEC 62271-202 "High and Low Voltage Preinstalled Substation" standard
Description
12/0.4KV HV power compact substation
Box type substation is designed as box type and specially for new energy generation industry, which can adjust the low voltage from inverter station to high voltage and then run in power grid. So a box-type inverter station and a step-up station can be integrated into one power generation station. It’s widely applied in Solar Energy Power Plant, Wind Energy Power Plant and Nuclear Power Plant, etc.
Main features:
1, high performance, high technology, 20 years of maintenance free.
2. The shell adopts double-layer, sealed, spray zinc anticorrosive structure, no rust for 20 years.Dust, moisture and condensation proof.
3. Compact and simple structure, large capacity, minimum floor area, quick installation.High and low pressure operation is convenient.
4, fully sealed and fully insulated structure, without insulation distance, reliable to ensure personal safety.The use of cable in and out of the line, without other distribution room.
5,Fully compartmentalized construction for MV switchgear, transformer and LV switchgear
Ambient condition:
1. Ambient temperature: -25 ℃~+40℃ ;
2. Altitude: ≤1000m;
3. Wind pressure:≤ 700Pa;
4. Humidity: daily average ≤95%, monthly average ≤90%;
5. Pollution degree:IP54
Structure of European style box transformer
In China, European style box type substations are commonly used, with three parts each consisting of one room, forming a "mu" or "pin" structure. Commonly used models include ZBW and XWB. The cross-sectional and wiring diagrams are shown in Figure GYPD00102003-1. The high voltage chamber of the European style box transformer is a ring network, double line or terminal unit load switch, with a small volume and compatibility with the ring network cabinet. Adopting a safe and reliable compact design, with comprehensive anti misoperation interlocking function, high reliability, and convenient operation and maintenance. High voltage equipment generally adopts a combination of load switch and fuse. The fuse is equipped with an impactor. After the fuse is blown, the striker will push the release mechanism, and the load switch three-phase will jump open at the same time to avoid phase loss operation. At the same time, if an electric operating mechanism is used, distribution automation function can be implemented. The 10kV cable outlet of the ring network structure is equipped with a ground fault indicator and zero sequence sensor. Transformers can be oil immersed or dry type, with D, yn11 wiring. Considering unfavorable heat dissipation, natural ventilation or top forced ventilation can be used. The low-voltage room is equipped with metering and reactive power compensation, and the secondary circuit and number of outgoing lines can be designed according to user needs to meet different needs. The outer shell is made of steel plate or alloy plate, with a double-layer top cover and good insulation. The appearance and color can be coordinated with the environment. The high-voltage chamber, transformer chamber, and low-voltage chamber are separated into independent compartments by partitions. For monitoring and maintenance, lighting devices are installed in each compartment, and the lighting switch is controlled by the door
Operation of Box Substation
1. The box type substation should be placed at a relatively high place, not in low-lying areas, to prevent rainwater from entering the box and affecting equipment operation. When pouring concrete platforms, gaps should be left on the high and low voltage sides to facilitate the laying of cables in and out. When excavating the foundation, if encountering the ground formed by the accumulation of garbage or corrosive soil, it must be excavated to solid soil, then backfilled with good soil quality and compacted, and then filled with three layers of soil or gravel to ensure the stability of the foundation.
2. The grounding and neutral connection of the box type substation share a common grounding network. The grounding grid generally adopts the method of driving grounding piles at the four corners of the foundation, and then connecting them as a whole. There must be two reliable connections between the box type substation and the grounding grid. After operation, the grounding connection should be checked regularly to ensure it is not loose or corroded. Regularly measure the grounding resistance, not exceeding 4 Ω.
3. The box type substation mainly adopts natural air circulation cooling. Therefore, debris should not be piled up around it, especially the transformer room door. Louver ventilation holes should also be regularly removed to ensure that the equipment does not exceed the maximum allowable temperature.
After the low-voltage circuit breaker trips, the cause should be identified before power can be transmitted to prevent the accident from expanding.
5. The high-voltage chamber of the box type substation should be equipped with zinc oxide lightning arresters, and the installation method should be convenient for testing and replacement.
6. Equipment such as ring network switches, transformers, lightning arresters, etc. in the high-voltage room should be regularly inspected and maintained, defects should be discovered and dealt with in a timely manner, and insulation preventive tests should be conducted regularly. If it is discontinued for more than 3 months and is put into operation again, a full project preventive test should be conducted.
7. To replace a high-voltage fuse without breaking capacity, the transformer must be powered off, and the mechanical interlock must be properly released during operation, and an insulated operating rod must be used.
8. All incoming and outgoing cable holes of the box type substation should be sealed to prevent small animals from entering and causing accidents.
9. Must have a warning sign of "high voltage danger" and a nameplate number for electrical equipment
Technical parameters(for reference, can also be customized):
Items | Value | ||
Rated voltage | Primary | 0.11KV,0.22KV,0.4KV | |
Secondary | 11kV,15KV,24KV,33KV,110KV | ||
Rated current | High voltage circuit | 400~1250A | |
Low voltage circuit | 630~3150A | ||
Rated frequency | 50Hz | ||
Rated power | 800,1250; 1600; 2000~5000kVA | ||
Rated insulation level | High voltage side | Power frequency | 95kV |
impact | 185kV | ||
Low voltage side | Power frequency | 42kV | |
impact | 75kV | ||
Rated short time withstand current | High voltage side | 20; 25; 31.5kA | |
Low voltage side | 25; 31.5; 40kA | ||
Rated peak withstand current | High voltage side | 50; 63; 80kA | |
Low voltage side | 63; 80; 100kA | ||
Insulation level of transformer | Power frequency | 65kV | |
Impact | 185kV | ||
Insulation level of subsidiary circuit | 2kV | ||
PRODUCT PHOTO








FAQ
Q5 : Is OEM/ODM available?
A: Yes, it is! Our products can be Customized. We have design and engineer teams,we can customize products according to customers' drawing or requirements.
Q6 : You are manufacturer or trading company?
A: We are factory, As a 100% professional manufacturer with 20 year's manufacturer experience, we could produce products according to customers' requirements and we could also control the quality of products 100%.
Q7 : Can the price be negotiated?
A: Yes, the price is negotiable. It can be changed according to your quantity or package
Q8 : How about inspection?
A: We have the whole inspection system from raw material to end products include temperature rise test,salt spraying test conductor type test,mechanical life test.
Q9 : What is payment terms?
A: T.T, Paypal,Western Union,Alibaba trade assurance and L/C is acceptable. 30% T/T in advance ,70% balance before shipment.
Q10 : What is the service offered by company?
A: We have the professional engineer team which can design and develop the mold to arrive different customer requirement.
We also have the sales team to offer good service from pre-sale to after-sale.
MORE VIDEO INTRODUCTION
https://www.facebook.com/bob.niu.35/
Youtube
www.youtube.com/channel/UC5IP4dL0UTQG4fgAOa3UhWA
https://twitter.com/FengyuanE
This product is usually customized.
We are a manufacturer and have a professional technical department that can design and provide solutions according to customer needs.
Please contact our sales personnel to obtain design drawings
Here are our customer examples for your reference
Afghan clients
| TECHNICAL REQUIREMENTS AND CHARACTERISTICS OF EQUIPMENT | ||||
| Re:82 sets compact substation | ||||
| Item- No. | Schedule of Technical Data | Unit | Required (at 3000 m | Offered Data |
| System Data Requirements | ||||
| 1.05.10 | Stranded copper conductor for earthing | |||
| Manufacturer | - | |||
| Material | - | copper | ||
| Cross-section | mm2 | >50 | ||
| Length | m | >40 | ||
| 1.05.11 | Earthing rods | |||
| Manufacturer | - | |||
| Type | - | |||
| Materia! | - | |||
| Length | m | |||
| Sections per rod | pcs | |||
| 1.6 | Compact Substations (Option 1) | |||
| Manufacturer | - | fengyuan | ||
| Type | - | OutDoor | ||
| Overall protection class for complete substation | - | IP 44 | IP 44 | |
| Material of enclosure | - | GI | ||
| Overall dimensions (W x L x H) | ||||
| for S/S with 1x50 kVA transformer | mm/mm/mm | 3000x1850x2150 | ||
| ■ for S/S with 1x100 kVA transformer | mm/mm/mm | 3000x1850x2150 | ||
| for S/S with 1x160 kVA transformer | mm/mm/mm | 3000x1850x2150 | ||
| • for S/S with 1x250 kVA transformer | mm/mm/mm | 3000x1850x2150 | ||
| Overall weight | ||||
| ■ for S/S with 1x50 kVA transformer | kg | 1000kg. | ||
| ■ for S/S with 1x100 kVA transformer | kg | 1000kg. | ||
| ■ for S/S with 1x160 kVA transformer | kg | 1000kg. | ||
| ■ for S/S with 1x250 kVA transformer | kg | 1000kg. | ||
| 1.6.1 | 20 kV Switchgear equipment | |||
| Manufacturer | - | Chnt / Equivalent | ||
| Type | - | Indoor RMU | ||
| Rated voltage | kV | 20 | 20 | |
| Maximum operating voltage | kV | 24 | 24 | |
| Rated current | A | 400 | 400 | |
| Rated short time current | kA | 16 | 16 | |
| Rated power frequency withstand voltage | kV | 50 | 50 | |
| Rated impulse withstand voltage (peak value) | k-^peak | 125 | 125 | |
| Insulating medium | SF6/air | SF6/air | ||
| Protection class | lP4x | lP4x | ||
IF NEED MORE DETAILES,PLEASE FEEL FREE YO CONTACT US
Welcome to inquiry
Contact information:
Jiyuan Fengyuan Electrical Equipment Co., Ltd
Sales Department
Contact person:Mr Charles Du
E-mail:fengyuan800@outlook.com
Mobile:+8618639199897(Available for whatsapp,wechat,skype)
Add:Huling industrial zone,jiyuancity,henan province,China
TEL:+86-0391-2180800
FAX:+86-0391-2180818
Hot Tags: 12/0.4kv hv power compact substation, China, manufacturers, suppliers, customized