
Digital Type Hipot Kit Oil Immersed Type Hv Test Transformer
The overhead transformer can be used alone to provide a single-phase load, or as one of the three units in a group to provide a three-phase load. It is oil immersed type transformers. The device can be directly installed on wooden poles or concrete poles, or clusters can be installed on poles...
Description
We are able to supply you with high quality and highly efficient distribution transformers, Withdrawable Fixed Type Circuit Breaker, 12kv RMU since we have experienced technicians and skilled workers. We will sincerely cooperate with friends from all walks of life with our excellent products and perfect service, and welcome new and old customers to visit our company, discuss cooperation and work together for common benefit. Our company is based on a rigorous and realistic scientific attitude with unswerving professionalism.
Single Phase Pole Mounted Transformers
The overhead transformer can be used alone to provide a single-phase load, or as one of the three units in a group to provide a three-phase load. It is oil immersed type transformers. The device can be directly installed on wooden poles or concrete poles, or clusters can be installed on poles for three-phase use. Our single-phase overhead distribution transformers are usually used in rural areas, remote areas and scattered villages and other places to provide high-quality power for daily lighting, agricultural production and industrial plants. In addition, it is also suitable for energy-saving projects in railways and urban power grids.
In Western developed countries, Southeast Asia, North and South America, a large number of single-phase transformers are used as distribution transformers. In the power distribution network with distributed power supply, single-phase transformers have great advantages as distribution transformers. It can reduce the length of low-voltage power distribution lines, reduce line losses, and improve power supply quality. In recent years, my country's State Grid has also gradually begun to promote pilot single-phase transformers in some areas. The pole-mounted single-phase transformer produced by Fengyuan adopts a high-efficiency and energy-saving wound core structure design and adopts a pole-mounted suspension installation method, which is small in size, small in capital investment, reduces the low-voltage power supply radius, and can reduce low-voltage line losses by more than 60%.
1、 What is an oil immersed transformer?
Oil immersed transformer, also known as oil immersed transformer, is a transformer device that uses oil cooling to reduce the temperature of the transformer. Unlike dry transformers, the main body of an oil immersed transformer is installed in a welded steel oil tank filled with insulating oil. When an oil immersed transformer is in operation, the heat from the coil and iron core is first converted into insulating oil and then into cooling medium. According to the capacity, it can be divided into immersed Free cooling transformer and immersed forced air cooling transformer.
2、 The structure and working principle of oil immersed transformers
Oil immersed transformers are structurally similar to transformers It is one of the types of transformers classified according to the insulation form of the iron core. Therefore, it has recognizable features of oil immersed coils, which can reduce the heat map of the equipment inside.
The basic components of the oil immersed type are composed of magnetic cores, windings, and bushings. The magnetic core provides a path for magnetic flux. The winding creates a magnetic field consisting of a conductor coil wound around an iron core and insulated with a cardboard barrier and shielding layer. The thickness of the winding insulation layer increases with increasing voltage. The bushing connects the transformer winding to the substation.
Oil type transformers are used for power distribution or substations. Their core and coils are immersed in oil, which can cool and insulate. Oil circulates through the pipes in the coil and around the coil and iron core components through convection. The oil is cooled externally by the fuel tank at low rated values, and by an air-cooled radiator at high rated values.
3、 Types of oil immersed transformers
There are two main types of oil immersed transformers: single-phase transformer and three-phase transformer.
A. One phase oil immersed transformer
B. Three-phase oil immersed transformer
4、 Purpose of using oil immersed transformers
Oil type transformers can be installed on the ground, base, or pole for outdoor use. They provide efficient performance in various applications, including transmission and distribution networks, renewable energy generation, and small industries.
The oil transformer has a huge capacity, so it will save a lot of electricity, minimize energy loss, save energy, and reduce user costs. Not only that, the oil in the machine can also cool the internal wire cores, thereby improving the durability and electrical performance of transformer equipment.
5、 Precautions for using oil-immersed transformers
1. Oil immersed transformers use oil for operation, so the quality of the oil will significantly affect the lifespan and safety of the transformer.
2. During use, it is necessary to regularly inspect and maintain the transformer system to ensure the normal and safe operation of the machine. Otherwise, there is a high risk of problems and extreme danger.
3. The waste generated by petroleum is prone to polluting the environment and affecting the lives of surrounding people. Therefore, the gradual disposal of waste is also important
Product features in transmission overhead structure system:
• The product can be operated in single-phase, or 3 single-phase groups as three-phase operation
• Simple and quick installation
• Beautiful and modern appearance
• Excellent insulation and sealing system
• Higher system reliability
• Lower operating costs
Provide two types of single-phase distribution transformers
Common type and full self-protection type
Silicon steel sheet and amorphous alloy cores
Product Specifications
Frequency: 50 or 60Hz
Capacity range kVA: 5~500
Primary Voltage: 2.4kV-35kV
•Secondary Voltage: 120-600V
| Rated Capacity | Voltage group(KV) | Loss(KW) | No-load current | Impedance | Weight(kg) | ||||
| (KVA) | HV | LV | No-load | Load | % | % | Machine | Oil | Gross |
| 5 | 13.8 | 0.22 | 35 | 145 | 4 | 3.5 | 50 | 40 | 130 |
| 10 | 13.2 | 0.24 | 55 | 260 | 3.5 | 65 | 40 | 150 | |
| 16 | 11 | 65 | 365 | 3.2 | 80 | 40 | 180 | ||
| 20 | 10.5 | 80 | 430 | 3 | 100 | 50 | 205 | ||
| 30 | 10 | 100 | 625 | 2.5 | 115 | 50 | 225 | ||
| 40 | 125 | 775 | 2.5 | 150 | 55 | 270 | |||
| 50 | 6.3 | 150 | 950 | 2.3 | 175 | 70 | 310 | ||
| 63 | 6 | 180 | 1135 | 2.1 | 190 | 80 | 340 | ||
| 80 | 200 | 1400 | 2 | 240 | 100 | 420 | |||
| 100 | 240 | 1650 | 1.9 | 295 | 100 | 490 | |||
| 125 | 285 | 1950 | 1.8 | 370 | 110 | 560 | |||
| 160 | 365 | 2365 | 1.7 | 430 | 130 | 650 | |||
PRODUCT PHOTO











OUR PRODUCT SERIES
LOW VOLTAGE SWITCHGEAR, GCS/MNS/GCK/GGD/SMC/JP/
HIGH VOLTAGE SWITCHGEAR,KYN28A/KYN61-40.5/SF6/XGN-12/HXGN
TRANSFORMER,H59/H61 OIL IMMERSED TRANSFORME,AND DRY TYPE TRANSFORMER
European box-type transformer substation
CERTIFICATE




EXHIBITION

Company Profile

Henan Fengyuan Power Technology Co., Ltd., founded in July 2010, has a registered capital of 20 million yuan, a fixed asset of 50 million yuan, more than 200 employees and an annual output value of nearly 100 million yuan. It's specialized in r&d and production of complete sets of high and low voltage equipment such as box-type substation, distribution cabinet/box, drawer cabinet, ring network cabinet, inflatable cabinet, cable distribution box,etc.And to undertake part of the power installation and line renovation projects. With the concept of "honesty, customer first",we will provide our customers with high quality and efficient service.
We provide competitive prices, high quality products, timely shipment and efficient services to develop our cooperation with all of our customers. We are trading in accordance with international traditions and practices. We would like to extend business with our customers and partners on the basis of cooperation and mutual benefit.
Production

PACKING&DELIVERY


FAQ
Q1: Is OEM/ODM available?
A1: Yes! Our products can be customized. We have a team of design and engineers, and can customize products according to customers' drawings or requirements.
Q2: What is your MOQ?
A2: One set.
Q3: How about the delivery time?
A3: It depends on your order quantity, it usually takes about 30 days.
Q4: How do you control the quality?
A4: We have a quality control team to ensure quality, and every step meets the standards. At the same time, if necessary, we will take pictures and shoot videos for you. Before packaging and shipping, all products will be fully assembled and carefully tested.
MORE VIDEO
https://www.facebook.com/bob.niu.35/
Youtube
www.youtube.com/channel/UC5IP4dL0UTQG4fgAOa3UhWA
https://twitter.com/FengyuanE
This product is usually customized.
We are a manufacturer and have a professional technical department that can design and provide solutions according to customer needs.
Please contact our sales personnel to obtain design drawings
Here are our customer examples for your reference
Togo customer
DESIGNATIONS | UNITS | SPECIFIC DATA | CANDIDATE DATA |
Maker | To be indicated | ||
Reference standard | IEC 60076 | ||
Type | Phase | ||
Vat | Hermetic | ||
Execution | Tropicalized | ||
Dielectric | PCB-free oil | ||
Installation | On pole | ||
Operating ambient temperature | °C | 45 | |
Rated frequency | Hz | 50 | |
Rated power | Kva | 100 | |
Rated primary voltage | Kv | 20 | |
Isolation level assigned to primary school | Kv | 24 | |
Number of phases in primary school | 03 | ||
Secondary voltage | V | 400/230 | |
Voltage adjustment range on the M side when unladen | % | ±2.5 | |
Coupling | DYn11 | ||
Short circuit voltage | % | 4 – 4.5 | |
Neutral sized for one load | % | 100 | |
Maximum vacuum losses | W | 230 - 460 | |
Losses due to Maxi load | W | 1450 - 2350 | |
Maximum steady-state oil temperature | °C | 55 | |
Maximum temperature of the windings in steady state | °C | 60 | |
Winding material | Electrolytic copper | ||
Maximum noise level | Db | 52 | |
50Hz industrial frequency hold, 1 min | Kv | 50 – 70 | |
Shock wave resistance (1.2/50 micros) | Kv | 125 - 170 | |
Cooling | ONAN | ||
Nameplate | 01 | ||
Grounding connection | 01 | ||
Dimensions Height/width/depth | mm x mm x mm | 1200 X 1270 X 820 | |
Total mass of transformer including oil | Kg | 700 | |
Oil mass | Kg | 160 | |
PAINT | |||
§ Tropicalized and anti-rust | |||
Number | § Layers | ||
§ Binder | |||
§ Colour | |||
Plans and technical diagrams to be provided. | |||
Welcome to inquiry
Contact information:
Jiyuan Fengyuan Electrical Equipment Co., Ltd
Sales Department
Contact person:Mr Charles Du
E-mail:fengyuan800@outlook.com
Mobile:+8618639199897(Available for whatsapp,wechat,skype)
Add:Huling industrial zone,jiyuancity,henan province,China
TEL:+86-0391-2180800
FAX:+86-0391-2180818
We aim to create much more worth for Digital Type Hipot Kit Oil Immersed Type Hv Test Transformer. First business, we learn each other. Now many OEM factories cooperated with us too.
Hot Tags: Single Phase Pole Mounted Transformers, China, manufacturers, suppliers, customized, Circuit Breaker, switch cabinet, Box Type Compact Substation, insulated ring main unit switchgear, transformer type substation, SF6 insulated switch cabinet
[[ProKeywords]]





